My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
STRATFORD
>
1249
>
3600 - Recreational Health Program
>
PR0360170
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/16/2020 4:26:47 PM
Creation date
7/16/2020 4:26:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0360170
PE
3611
FACILITY_ID
FA0001320
FACILITY_NAME
VILLAS, THE
STREET_NUMBER
1249
STREET_NAME
STRATFORD
STREET_TYPE
CIR
City
STOCKTON
Zip
95207
APN
10814002
CURRENT_STATUS
01
SITE_LOCATION
1249 STRATFORD CIR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Time In: <br /> 2:59 pm <br /> 1:30 pm <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: BURGER, EUGENE J & SHIRLEY R <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 1249 STRATFORD CIR, STOCKTON 95207 <br />Date: 08/01/2018Name of Facility: VILLAS, THE <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #7 Pool Deck <br />OBSERVATIONS: The water level in the pool is higher than the surrounding ground level. I noticed minor flooding by the <br />Junction box that houses the GFI breaker for the pool light. According to Maintenance this was pool water leaking from the <br />pool. Ensure that there are no leaks in the pool. <br />CALCODE DESCRIPTION: An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 3114B) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #8 Pool and Deck Lighting <br />OBSERVATIONS: During the inspection the pool light could not be turned on. The operator must maintain adequate lighting <br />for the entire pool during dark hours. Provide a functional light for the pool. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Replace missing float valve assembly. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br /> #37 Electrical Hazards <br />OBSERVATIONS: During inspection I noticed the GFI breaker was not functioning properly, maintenance staff replaced GFI <br />breaker for the pool light on site. GFI breaker functions properly now. <br />CALCODE DESCRIPTION: Electrical equipment installed in the water, walls, deck, or equipment room of a public pool shall comply with <br />California Electrical Code. (CEC 680.4) Light fixtures installed in the pool that operate at more than 15 volts shall be protected by a ground <br />fault circuit interrupter. (CBC 3160B) <br />Page 1 of 2EHD 36-01 Rev. 06/30/15 Swimming Pool OIR <br />FA0001320 PR0360170 SC001 08/01/2018 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com
The URL can be used to link to this page
Your browser does not support the video tag.