Laserfiche WebLink
Chevron Monitoring Certification Checklist <br /> Store Number : 307709 Address : 10858 TRINITY PKWY STOCKTON, CA 95219 <br /> Date : 3/ 13/ 2020 Technician : Jesus Saldivar Company: TANKNOLOGY INC. <br /> Step Instruction Tl T-2 T-3 <br /> Product UNLEADED PREMIUM Diesel <br /> Tank Type <br /> (DW FRP, DWSteet SW FRP) Fiberglass Fiberglass Fiberglass <br /> 1 Annular Riser Height ( measured ) <br /> 2 Tank Diameter: (from tank chart, 118 .00 in. 118. 00 in. 119 . 50 in. <br /> for example : 118. 375 '; 117. 75 '; Ill '; 92 '; etc. ) <br /> 3 For FRP tanks, 1/2 circumference of the tank 185 . 26 in. 185 . 26 in. 187 . 62 in. <br /> (o. s x 3. 14 x tank diam.) OR (4.57 x step 2) <br /> Required annular sensor length : <br /> 4 FRP = Riser + 112 Circumference = step / + step 3 185 . 26 in. 185 . 26 in. 187 . 62 in. <br /> Steel = Riser + diameter = step 1 + step 2 <br /> Mark & label the required sensor length on <br /> 5 sensor cord . Label should be under the cap & Yes Yes Yes <br /> serve to prevent the cord being pulled too short. <br /> Is tank annular sensor in the correct position ? <br /> Yes Yes Yes <br /> 6 FRPTanks: with the marked required length <br /> lining up with the top of the annular riser? Yes Yes Yes <br /> Steel Tanks: sensor touching bottom with slack <br /> above the marked required sensor length ? <br /> Are the DW pipe boots pulled back in tank sumps? <br /> 8 (YIN or N/A, note if can 't be verified because Yes Yes Yes <br /> clamshell pointing down) <br /> Are tank sump sensors back in their holders and <br /> 9 in the correct position ? Yes Yes Yes <br /> (YIN or N/A document with photo) <br /> 7 Approximate gallons of product dispensed for <br /> purging, etc. and returned to tank <br /> Has the Veeder Root Battery been replaced & dated prior to failsafe ? <br /> (If battery backup failed, label and leave failed battery on top of console, note in comments and advise your OM) Replaced in Last 30 Days <br /> i <br /> Has Veeder Root Programming before & after testing been printed & verified ? <br /> (especially tank manifolding setup - see Note 2) Yes <br /> i <br /> Has Veeder Root Programming before & after been attached to the Work Order? Yes <br /> i <br /> Have all sensor model numbers been verified against the Veeder Root cord label ? <br /> Make a note sensor label missing or illegible, & approx. cord length for -208/-209 with missing labels Yes <br /> if <br /> Additional Comments : <br /> ALL SITE ANNULARS ARE 303 BRINE SENSOR , TESTED AND PASSED. . . <br /> Note 1: Certain Veeder Root Software versions will automatically revert to the default tank manifold settings anytime the programming is changed, such as when sensors are <br /> temporarily X'ed out, etc. <br />