SAN J O A R N Environmental Health Department <br /> i y �V <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GRIN INVESTMENTS INC DBA:ARCO AM/PM 6009 N EL DORADO ST, STOCKTON November 18, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 204 CCR 2712(b)(6) Failure to maintain records of repairs, lining, and upgrades on site,for the life of the UST. <br /> OBSERVATION: Records of repairs, linings, and upgrades for the UST system were not found on site. Work orders <br /> for the 08/20/2020 91 line leak detector replacement was not on site. <br /> REGULATION GUIDANCE: These records shall be kept on site for the life of the tank. <br /> CORRECTIVE ACTION: Immediately locate and maintain these records on site and submit copies to the EHD. <br /> This is a minor violation. <br /> 205 CCR 2712(i) Failure to have current UST Monitoring Plan readily accessible at the facility. <br /> OBSERVATION:An approved copy of the monitoring plans were not available for inspection. <br /> REGULATION GUIDANCE:A copy of these plans shall be accessible on site at all times. <br /> CORRECTIVE ACTION: Immediately locate and retain a copy on site. <br /> This is a repeat violation, Class II. <br /> 208 CCR 2716(a-e) Failure to comply with the designated operator inspection requirements. <br /> OBSERVATION: The designated operator failed to check and note all required items on the visual inspection <br /> reports.The incorrect and missing information included the following from the inspection reports: <br /> -alarms were not addressed on monthly reports <br /> -overfill prevention test date missing <br /> REGULATION GUIDANCE: During the visual inspection,the designated operator shall check that all required <br /> testing and maintenance for the UST system have been completed and shall check all required items on the report. <br /> CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including <br /> all of the required information on the reports. <br /> This is a minor violation. <br /> 304 CCR 2631(a); HSC 25290.1(c) Failure to construct, operate, and maintain primary containment as product-tight. <br /> OBSERVATION: Liquid was observed in the 1/2, 5/6, and 11/12 under dispenser containment, indicating a leak in <br /> the primary containment. <br /> REGULATION GUIDANCE:All primary containment for the UST system must be product tight. <br /> CORRECTIVE ACTION: Immediately have a properly licensed,trained, and certified contractor repair or replace the <br /> failed component(s), under permit and inspection of the EHD if necessary. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> FA0024188 PR0542116 SCO01 11/18/2020 <br /> EHD 23-01 Rev.9/16/2020 Page 7 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />