Laserfiche WebLink
SYSTEM SET-UP REPORT (Page 2) <br /> -- — YLLL LINt U15AbLt �GIUY <br /> l' 3:DIESEL LEAK TEST THOD - -- - <br /> - - - - - - - - <br /> PRODUCT CODE 3 - - - - - - - - - - LIQUID-SENSOR-SETUP- - <br /> THERMAL COEFF :.004500 TEST ON DATE : ALL TANK Q I :REGULAR <br /> TANK DIAMETER 118.30 JAN 9, 2017 L I :REGULAR ANNULAR <br /> TANK PROFILE 4 PTS START TIME : DISABLED DIAL POINT HYDROSTATIC IN-TANK ALARMS <br /> FULL VOL 11904 TEST RATE :0.20 GAL/HR CATEGORY : ANNULAR SPk'E T I :HIGH WATER ALARM <br /> 88.7 INCH VOL 9710 DURATION 2 HOURS T l:LOW PRODUCT ALARM <br /> 59.2 INCH VOL 5944 .1 <br /> 29.6 INCH VOL 2186 TST EARLY STOP:DISABLED LIQUID SENSOR ALMS <br /> L.2:REGULAR STP SUMP L 2:FUEL ALARM <br /> LEAK TEST REPORT FORMAT DW SUMP 2-1 L 9:FUEL ALARM <br /> FLOAT SIZE: 4.0 IN. PS NORMAL CATEGORY : STP SUMP L10:FUEL ALARM <br /> WATER MINIMUM 0.000 - <br /> L11:FUEL ALARM <br /> PRESSURE LINE LEAK SETUP L12:FUEL ALARM <br /> WATER WARNING 1.5 - - - - - - - - - - - - L 39REGULAR FILL SUMP L 2:SENSOR OUT ALARM <br /> HIGH WATER LIMIT: 2.0 DW SUMP 2-1 L 9:SENSOR OUT ALARM <br /> WATER ALARM FILTER: LOW% CATEGORY : PIPING SUMP LIO:SENSOR OUT ALARM <br /> Q I:REGULAR LII:SENSOR OUT ALARM <br /> MAX OR LABEL TYP:2.Oi3.01N FIBERGLASSL12:SENSOR GUT.,ALARM <br /> VOLUME 11904 L 4:PkEMIUM-DSL ANNULAR <br /> 2.OIN DIA LEN: 210 FEET DUAL POINT HYDROSTATIC SMARTSENSOR ALARMS <br /> HIGH PRODUCT3.OIN DIA LEN: 0 FEET CATEGORY : ANNULAR SPACE s 5:HIGH LIQUID ALARM <br /> % MAX 95.0 ISD SITE ALARMS <br /> (GALLONS) 11309 SHUTDOWN RATE: 3.0 GPH ISD GROSS PRES-FAIL <br /> LOW PRESSURE SHUTOFF:NO L 5:PREMIUM STP SUMP ISD-DEGRD PRES FAIL <br /> VERFILL LIMIT LOW PRESSURE 0 PSI DW SUMP 2-1 ISD VAPOR LEAK FAIL <br /> % MAX 90.0 CATEGORY : STP SUMP -ISD VP PRES FAIL <br /> (GALLONS) 10714 T I :REGULAR ISD VP STATUS FAIL <br /> DISPENSE MODE: <br /> : £LIVERY LIMIT STANDARD L 6:PREMIUIl FILL SUMP ISD HOSE ALARMS <br /> % MAX 10.0 SENSOR: NON-VENTED DW SUMP 2-1 ALL:GROSS COLLECT FAIL <br /> (GALLONS) 1190 PRESSURE OFFSET: O.OPS1 CATEGORY : PIPING SUMP .14L.L:DEGRD COLLECT FAIL <br /> LOI,A PRODUCT MECHANICAL BLENDER: NO ALL:FLOW COLLECT FAIL <br /> VOLUME 1000 L 7:DIESEL STP SUMP Q 2:PREMIUM <br /> Q 2:PREMIUM DW SUMP 2-1 <br /> LEAK ALARM LIMIT: 9y CATEGORY : STP SUMP IN-TANK ALARMS <br /> .-SUDDEN LOSS LIMIT: 99 TYP:2,.0:3.01N FIBERGLASS T 2:HIGH WATER ALARM <br /> TANK TILT 0.00 2.DIN DIA LEN: 180 FEET T 2:LOW PRODUCT ALARM <br /> PROBE OFFSET 0.00 L B:DIESEL FILL SUMP <br /> 3.OIN DIA LEN: 0 FEET DW SUMP 2-1 LIQUID SENSOR ALMS <br /> SIPHON MANIFOLDED TANKS CATEGORY : PIPING SUMP L 5:FUEL ALARM <br /> NONE SHUTDOWN RATE: 3.0 GPH L 9:FUEL ALARM <br /> LINE MANIFOLbED TANKS LOW PRESSURE SHUTOFF:NO L10:FUEL ALARM <br /> LOW PRESSURE 0 PSI L 9:DISP 1-2 PAN LII:FUEL ALARM <br /> TO: NONE DW SUMP 2-1 L12:FUEL ALARM <br /> T 2:PREMIUM CATEGORY : DISPENSER PAN L 5:SENSOR OUT ALARM <br /> DISPENSE MODE: L 9:SENSOR OUT ALARM <br /> LEAK MIN PERIODIC: 0'- <br /> STANDARD LIO:SENSOR OUT ALARM <br /> 0 SENSOR: NON-VENTED L11 :SENSOR OUT ALARM <br /> PRESSURE QFFSET: O.OPSI L10:DISP 3-4 PAN L12:SENSOR OUT ALARM <br /> ..EAR: MIN ANNUAL 0% DW SUMP 2-1 <br /> 0 MECHANICAL BLENDER: NO CATEGORY : DISPENSER PAN SMARTSENSOR ALARMS <br /> - s 7:HIGH LIQUID ALARM <br /> ERIODIC TEST T`.FE Q 3:DIESEL <br /> !SD SITE ALARMS <br /> STANDARD <br /> TYP:2.0,,3.OIN FIBERGLASS LiI :DISP 5-6 PAN ISD GROSS PRES FAIL <br /> rJNUHL TEST FAIL 2.01N DIA LEN: 190 FEET DW SUMP 2-1 ISD DEGRD ?RES FAIL <br /> ALARM DISABLED CATEGORY : DISPENSER PAN ISD VAPOR LEAK FAIL <br /> 3.O1N DIN LEN: O FEET ISD VP PRES FAIL <br /> :ERIODIC TEST FAILISD VP STATUS FAIL <br /> ALARM DISABLED SHUTDOWN RATE: 3.0 GFH <br /> LOW PRESSURE SHUTOFF:NO L12:DISP 7-8 F'HN ISD HOSE ALARMS <br /> :ROSS TEST FAIL LOW PRESSURE 0 PSI DW SUMP 2-1 ALL:GROSS COLLECT <br /> ALARM DISABLED CATEGORY : DISPENSER PAN ALL:DEGRD COLLECT FAIL <br /> T 3:DIESEL ALL:FLOW COLLECT FAIL <br /> ANN TEST AVERAGING: OFF DISPENSE MODE: <br /> IER TEST AVERAGING: OFF STANDARD Q 3:DIESEL <br /> SENSOR: NON-VENTED L13:VENT BOX <br /> TANK TEST NOTIFY: OFF PRESSURE OFFSET: O.OPS1 DW SUMP 2-1 1N-TANK ALARMS <br /> CATEGORY : PIPING SUMP T 3:HIGH WATER ALARI <br /> fNK TST SIPHON BREAKOFF MECHANICAL BLENDER: NO OUTPUT RELAY SETUP T 3:LOW PRODUCT ALAk19 <br /> DELIVERY DELAY 1 MIN LINE LEAK LOCKOUT SETUP - LIQUID SENSOR ALMS <br /> IP THRESHOLD 10.00% - - - - - - - - - - - - L 7:FUEL ALARM <br /> LOCKOUT SCHEDULE k I :UVERFILL L 9:FUEL ALARM <br /> DAILY TYPE: L1O:FUEL ALARM <br /> START TIME: DISABLED STANDARD L11 :FUEL ALARM <br /> STOP TIME : DISABLED NORMALLY OPEN L12:FUEL ALARM <br /> L 7:SENSOR OUT ALARM <br /> TANK 0: NONE L 9:SENSOR OUT ALARM <br /> LIO:SENSOR OUT ALARM <br /> - NO ALARM ASSIGNMENTS - L11 :SENSOR OUT ALARM <br /> L12:SENSOR OUT ALARM <br /> SMARTSENSOR ALARMS <br /> s10:HIGH LIQUID ALARM <br /> C 2018 Walton Engineering.hu. <br />