COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
255
>
2300 - Underground Storage Tank Program
>
PR0537549
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/31/2020 1:41:48 PM
Creation date
7/20/2020 9:47:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0537549
PE
2351
FACILITY_ID
FA0021617
FACILITY_NAME
HARNEY LANE AM PM
STREET_NUMBER
255
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
062-580-40
CURRENT_STATUS
01
SITE_LOCATION
255 E Harney Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-- - - Q 2:PREMIUM <br /> L 7:DISP 1-2 UDC-HYDRO l'(\ OUTPUT RELAY SETUP \� <br /> DW SUMP 2-1 l\i - - - - - - - LIQUID SENSOR ALMS <br /> CATEGORY : DISPENSER PAN L 3:FUEL ALARM <br /> R 1 :OVERFILL HORN L 7:FUEL ALARM <br /> TYPE: L B:FUEL ALARM <br /> STANDARD L 9:FUEL ALARM <br /> L 8:DISP 3-4 UDCwHYDRO NORMALLY OPEN L10:FUEL ALARM <br /> DW SUMP 2-1 LII :FUEL ALARM <br /> CATEGORY : DISPENSER PAN TANK #: NONE L12:FUEL ALARM <br /> L13:FUEL ALARM <br /> L14:FUEL ALARM <br /> IN-TANK. ALARMS L 3:SENSOR OUT ALARM <br /> L 9:DISP 5-6 UDC-HYDRO ALL:OVERFILL ALARM L 7:SENSOR OUT ALARM <br /> DW SUMP 2-1 ALL:HIGH PRODUCT ALARM L B:SENSOR OUT ALARM <br /> CATEGORY : DISPENSER PAN L 9:SENSOR OUT ALARM <br /> L10:SENSOR OUT ALARM <br /> L11 :SENSOR OUT ALARM <br /> L12:SENSOR OUT ALARM <br /> L10:DISP 7-8 UDC-HYDRO L13:SENSOR OUT ALARM <br /> DW SUMP 2-1 L14:SENSOR OUT ALARM <br /> CATEGORY : DISPENSER PAN L 3:SHORT ALARM <br /> " L 7:SHORT ALARM <br /> L B:SHORT ALARM <br /> L 9:SHORT ALARM <br /> L11 :DISP 9-10-UDC-HEiRO LIO:SHORT ALARM <br /> DW SUMP 2-1 PLLD LINE DISABLE SETUP L11 :SHORT ALARM 6 <br /> CATEGORY : DISPENSER PAN - - - - - - - - - - - - L12:SHORT ALARM <br /> L13:SHORT ALARM <br /> Q 1 :REGULAR L14:SHORT ALARM <br /> L12:DISP 11-12UDC-HYDRO LIQUID SENSOR ALMS SMARTSENSOR ALARMS ~ <br /> DW SUMP 2-1 L 1 :FUEL ALARM s 2:FUEL ALARM <br /> CATEGORY DISPENSER PAN L 7:FUEL ALARM s 3:FUEL ALARM <br /> L 8:FUEL ALARM s 4:FUEL ALARM <br /> L 9:FUEL ALARM s 2:HIGH LIQUID ALARM <br /> L10:FUEL ALARM s 3:HIGH LIQUID ALARM <br /> L13:DI5P 13-14UDC-HYDRO L11 :FUEL ALARM s 4:HIGH LIQUID ALARM <br /> DW SUMP 2-1 L12:FUEL ALARM <br /> CATEGORY : DISPENSER PAN L13:FUEL ALARM ISD SITE ALARMS <br /> L14:FUEL ALARM ISD GROSS PRES FAIL <br /> L 1 :SENSOR OUT ALARM <br /> L 7:SENSOR OUT ALARM ISD DEGRD PRES FAIL <br /> L14:DISP 15-16UDC-HYDRO L 8:SENSOR.OUT ALARM ISD VAPOR LEAK FAIL <br /> DW SUMP 2-1 L 9:SENSOR OUT ALARM ISD VP PRES FAIL <br /> CATEGORY : DISPENSER PAN L10:SENSOR OUT ALARM ISD VP STATUS FAIL <br /> L11 :SENSOR OUT ALARM ISD SETUP FAIL <br /> L12:SENSOR OUT ALARM- ISD SENSOR OUT FAIL <br /> L13:SENSOR OUT ALARM <br /> L15:VENT SMP-HYDRO L14:SENSOR OUT ALARM ISD HOSE ALARMS <br /> DW SUMP 2-1 L 1 :SHORT ALARM ALL:GROSS COLLECT FAIL <br /> CATEGORY : OTHER SENSORS L 7:SHORT ALARM ALL:DEGRD COLLECT FAIL <br /> L B:SHORT ALARM ALL:FLOW COLLECT FAIL <br /> L .9:SHORT ALARM <br /> L10:SHORT ALARM Q 3:DIESEL <br /> L17:REGULAR ANNULAR L11 :SHORT ALARM <br /> DUAL POINT HYDROSTATIC L12:SHORT ALARM LIQUID SENSOR ALMS <br /> CATEGORY : ANNULAR SPACE L13:SHORT ALARM L 5:FUEL ALARM <br /> L14:SHORT ALARM L 7:FUEL ALARM <br /> L B:FUEL ALARM <br /> SMARTSENSOR ALARMS L13.:FUEL ALARM <br /> L18:PREM-DIES, ANNULAR s 1 :FUEL ALARM L14:FUEL ALARM <br /> DUAL POINT HYDROSTATIC s 3:FUEL ALARM L 5:SENSOR OUT ALARM <br /> CATEGORY ANNULAR SPACE s 1 :HIGH LIQUID ALARM L 7:SENSOR OUT ALARM <br /> s 3:HIGH LIGUJD ALARM L B:SENSOR OUT ALARM <br /> L13:SENSOR OUT ALARM <br /> ISD SITE ALARMS L14:SENSOR OUT ALARM <br /> ISD GROSS PRES FAIL L 5:SHORT ALARM <br /> ISD DEGRD PRES FAIL L 7:SHORT ALARM <br /> ISD VAPOR LEAK FAIL L 8:SHORT ALARM <br /> L13:SHORT ALARM <br /> ISD SETUP FAIL L14:SHORT ALARM <br /> ISD SENSOR OUT.• FAIL <br /> SMARTSENSOR ALARMS <br /> ISD HOSE ALARMS s 5:FUEL ALARM <br /> ALL:GROSS COLLECT FAIL s 6:FUEL ALARM <br /> ALL:DEGRD COLLECT FAIL s 5:HIGH LIQUID ALARM <br /> s 6:HIGH LIQUID ALARM <br />
The URL can be used to link to this page
Your browser does not support the video tag.