Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Page 1 of 6) <br /> This form must be used to document testing and servicing of underground storage tank (UST) monitoring equipment. A copy of this form <br /> must be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the local agency regulating the <br /> USTs within 30 days of the date of the monitoring system certification . <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Monitoring System Certification <br /> 10146143 103/11 /20 <br /> Business Name (Same as Facility Name or DBA — Doing Business As.) Building # <br /> Costco # 1031 Manteca <br /> Business Site Address City ZIP Code <br /> 2440 Daniel St . Manteca 95337 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone # <br /> Alltech Petro Inc . (209 ) 532 - 7320 Ext . <br /> Mailing Address <br /> P . O . Box 4208 <br /> Name of UST Service Technician Performing the Certification (Print as shown on the ICC Certification.) <br /> Isaac Anderson <br /> Contractor/Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> CA 623541 /09- 1749 8146912 06/ 12/20 <br /> Monitoring System Training and Certifications List all applicable certificationsj Expiration Date <br /> Veeder- Root Level IV # 1336878 10/22/20 <br /> Va orless LDT-890 LDT #2113 04/08/21 <br /> OPW # 100456 05/ 16/20 <br /> Phil-Tite # 1022863709 04/ 19/20 <br /> ilia RESULTS OF TESTING/SERVICING <br /> Indicate and attach the following reports if the monitoring equipment is capable of generating either. <br /> M Monitoring System Set-up ® Alarm History Report Y N NA <br /> Was any monitoring equipment replaced? ❑ M El <br /> (If "Yes, " identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below.) <br /> Was damage, debris, or liquid found inside any secondary containment systems? El ® E <br /> (If "Yes, " describe what was found in section IV below.) <br /> Is all monitoring equipment operational per manufacturer's specifications? ® El ❑ <br /> (If "No, " describe why in section 1V below.) <br /> IV. COMMENTS <br /> If directed to use this section, describe how and when the issues were or will be corrected. <br /> This is the upper console with all the liquid sensors . <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the equipment identified in this document was inspected/serviced in accordance with California Code of <br /> Regulations, title 23 , division 3, chapter 16, section 2638 and all information contained herein is true and accurate. Attached to <br /> this certification is information (e. g . , manufacturers' checklists , monitoring system set-up, alarm history report, etc.) necessary <br /> to verify that this information and howing the layout of UST system is complete and accurate . <br /> UST Service Technician Signature <br /> CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, Y = Yes, N = No, NA = Not applicable <br />