Laserfiche WebLink
Q4V, SAN 10AQUIN <br />COUNTY <br />cqa P Greatness grows here. <br />March 7, 2018 <br />Jorge Carona <br />Carona Fueling & Electric Inc <br />PO Box 6219, Whittier, CA 90609 <br />Re: Chevron <br />1434 W Yosemite Ave, Manteca CA 95337 <br />Environmental Health Department <br />Linda Turkatte, REHS, Director <br />Kasey Foley, REHS, Assistant Director <br />PROGRAM COORDINATORS <br />Robert McClellon, REHS <br />Jeff Carruesco, REHS, RDI <br />Rodney Estrada, REHS <br />Willy Ng, REHS <br />Muniappa Naidu, REHS <br />SR0078235 <br />The San Joaquin County Environmental Health Department (EHD) has completed the review of the <br />application for a permit to convert the existing midgrade UST product to the Diesel product, replace 4 <br />dispensers with 2 Ovation (3+0) and 2 Ovation (3+1) models, install a Diesel vent cap, install a bravo <br />conversion frame on all four dispensers, and install a FE Petro STP -MLD -D leak detector on the Diesel <br />tank on the underground storage tank (UST) system at the above noted address. The permit has been <br />approved with the following conditions: <br />Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br />any applicable permits and requirements. <br />2. Any changes in information and scope of work must be submitted to EHD for approval prior to <br />commencing work. All new addenda supersede the previous ones. <br />3. Contact John Alaniz at (209) 468-3147 to arrange the following inspection appointments (a 48- <br />hour notice is required for inspection appointments). Please be aware that inspections for <br />emergency work must be scheduled within five days of permit approval. <br />a. An ISD upgrade is going to be occurring as part of the service request. If it is <br />determined that a cold start is necessary, a copy of the alarm history shall be printed <br />prior to performing the "cold start" of the Veeder Root system and made available at the <br />time of EHD inspection. Functionality of the monitoring system must be verified to <br />ensure that monitoring has been restored to meet the requirements of Title 23 California <br />Code of Regulations and the Health & Safety Code. <br />b. Leak detector test: The new Diesel leak detector must be tested to confirm that the <br />device can detect a leak of 3 gallons per hour at 10 psi. <br />c. Verification that all potential dispenser piping leaks will be contained by the under <br />dispenser containment. Prior to this inspection, send in the Bravo Dispenser <br />Conversion Evaluation Form to the EHD. See the permit packet for the form. <br />d. Visual inspection of piping within all of the dispensers replaced. <br />e. Witness secondary containment testing on the diesel turbine sump and the 1/2 , 5/6 <br />under dispenser containers <br />Please be aware that the facility cannot operate the UST system or receive fuel in the <br />Diesel tank prior to the EHD inspection and approval. <br />4. Provide hazardous waste manifest for tank and piping rinsate within 180 days of waste <br />generation. <br />5. Any individual performing the work of a service technician must meet the following <br />qualifications: <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />