COMPLIANCE INFO_2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1434
>
2300 - Underground Storage Tank Program
>
PR0231465
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2020 1:53:30 PM
Creation date
7/20/2020 11:29:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231465
PE
2361
FACILITY_ID
FA0003739
FACILITY_NAME
Colonial Energy CE 40134 (DBA Power Mart)
STREET_NUMBER
1434
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1434 W Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
186
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Time In: <br />Time Out: <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br />fir. s a Telephone: (209) 468-3420 Fax: (209) 464-0138 Web: www.sogov.org/ehd <br />Underground Storage Tank Program Service Request Inspection Report <br />Name of Facility: Colonial Energy CE 40134 (DBA Power Mart) <br />Date: 10/05/2018 <br />Address: 1434 W Yosemite AVE , MANTECA 95337 <br />Requestor: JORGE CORONA, CORONA FUELING AND ELCTRIC INC <br />Telephone: (562) 262-8492 <br />Program Element: 2308 - UST RETROFIT <br />Request #: SR0078235 <br />Inspection Type: 298 - UST RETROFIT REPAIR INSPECTION <br />Onsite Service Technician: Juan J. Jauregui <br />ICC Service Tech/Installer Exp. Date: 08/30/2019 <br />Manufacturer training: INCON, 06/04/20 <br />OVERALL INSPECTION NOTES AND COMMENTS <br />NOTES <br />On site to witness the following: <br />- A 0.002 gallon per hour leak rate using the INCON system for 15 minutes in UDC 5/6 and UDC 7/8. Both UDC passed. This <br />test was performed by service technician Juan J. Jauregui ICC certifiction expiration date 8/30/19, INCON certification <br />expiration 6/4/19 <br />- Passing results for the Diesel tank to confirm that the device can detect a leak of 3 gallons per hour at 10 psi. This testing <br />was performed by service technician Nicholas Joane ICC certification expiration date 4/11/19 and VMI certification expiration <br />07/13/19. <br />This Service request is NOT completed the following need to be addressed: <br />-Hazardous waste manifest for tank and piping reinstate within 180 days of waste generated must be provided. <br />-Tank owner or operator shall log into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/ all <br />pertinent forms and update and submit the "UST monitoring plan" for this tank conversion. FURTHERMORE while the <br />inspector was on site, overfill prevention equipment inspection was conducted for all three tanks. The integrity of the Diesel <br />product tank spill container was compromised during the testing. After performing a 60 minute hydrostatic test the Diesel <br />product direct -bury spill container failed when tested. All spill containers shall have a minimum capacity of five gallons and be <br />capable of containing a spill or overfill until it is detected or cleaned up. IMMEDIATELY DISCONTINUE deposition of <br />petroleum into this tank until the component is repaired or replaced by a properly licensed, trained, and certified contractor <br />under permit and inspection of the EHD. The Diesel product fuel levels are at 4738 gallons. If the spill container can't be <br />replaced immediately, there is a possibility that the Diesel UST system may be red tagged to prevent fuel inputs. <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />Received by: Name and Title: Schelby Horton, Manager <br />EH Specialist: ZUNA BARKER Phone: (209) 953-7311 <br />FA0003739 SR0078235 SC298 10/05/2018 <br />EHD 23-01 Rev. 06/30/15 Page 1 of 1 Underground Storage Tank Program Service Request inspection Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.