My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1434
>
2300 - Underground Storage Tank Program
>
PR0231465
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2020 1:53:30 PM
Creation date
7/20/2020 11:29:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231465
PE
2361
FACILITY_ID
FA0003739
FACILITY_NAME
Colonial Energy CE 40134 (DBA Power Mart)
STREET_NUMBER
1434
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1434 W Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
186
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PRODUCT PIPING SUMP TESTING <br />Test Method By: <br />o Manufacturer 0 Industry standard Professional Engr Other (see below) <br />Test Method Uses: <br />IPressure r vacuum • Hydrostatic Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Description <br />Tank #1 <br />Tank product <br />87 Gasoline <br />Sump material <br />FRP <br />Sump diameter (inches) <br />45 <br />Sump depth (inches) <br />48 <br />Height from tank top to highest <br />18 <br />piping penetration (inches) <br />Height from tank top to lowest <br />2 <br />electrical penetration (inches) <br />Method of sump attachment to tank <br />Coller <br />Condition of sump prior to testing <br />Dry <br />Portion of sump tested <br />Entire <br />Is system programmed for fail-safe operation? <br />Unknown <br />Was fail-safe verified to be operational? <br />No <br />Was sensor removed for testing? <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Depth of water level from tank top (inches) <br />20 <br />Wait time for water level to stabilize (hr:min) <br />:15 <br />Test start time <br />11:03 AM <br />Initial Probe Reading <br />2.8860 <br />Test end time <br />11:18 AM <br />Final Probe Reading <br />2.8855 <br />Test duration (hr:min) <br />0:15 <br />Change in water level (± 0.0000 inches) <br />-0.0005 <br />Pass/Fail threshold (±0.002 inches 11 Hr.) <br />0.0020 <br />TEST RESULT <br />PASS <br />Comments: <br />02017 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.