My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1434
>
2300 - Underground Storage Tank Program
>
PR0231465
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2020 1:53:30 PM
Creation date
7/20/2020 11:29:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231465
PE
2361
FACILITY_ID
FA0003739
FACILITY_NAME
Colonial Energy CE 40134 (DBA Power Mart)
STREET_NUMBER
1434
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1434 W Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
186
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. Verify that the water level will not cover electrical threaded connections before water <br /> testing. If the water will exceed threaded connections to the dispenser conduit seal off one <br /> must ensure no water will enter through that point. This assumes that the conduit threaded <br /> connections are not liquid tight. Visual testing only allowed on initial installation to pass <br /> NO drips leaks are allowed. If outside of sump can not be observed a minimum 5 hour test <br /> must be observe with a level drop no greater than 1/8". Alternative testing can be used such <br /> as electronic level probe, which can use its accuracy to reduce test time. <br /> 7. E.g Data collection time Typical 12"x 32"Box and fail rate of.05 GPH <br /> Failure,if rate exceeds Resolution/accuracy Data Time <br /> 0.0030 in 6 minutes Better than .0005" 6 minutes <br /> 0.0070 in 15 minutes .001 to .002" 15 minutes <br /> 0.0150 in 30 minutes .002 to .003" 30 minutes <br /> 8. After the completion of the water test, certify if the test has passed based on the schedule <br /> above. If you experience problems contact Bravo for assistance(323)888-4133. <br /> 9. Remove water and properly dispose of and manually dry float cup area. Next, remove <br /> weight off the float, if applicable, and make sure the chain is properly adjusted as indicated <br /> on installation maintenance instructions. This includes verification of float trip function and <br /> proper lead seal crimping to prevent future tampering. To adjust chain,refer to Bravo <br /> Installation Instructions page 7 of B2000 Shallow Box and page 6 of the B-8000 Deep Box. <br /> 10. NOTE: If Local Jurisdictions have high requirements than these please use their test <br /> protocols. <br /> Thank You, <br /> Don Mukai P.E. <br /> Bravo Engineering <br /> f:\engineering\winword0ocumentOut\Doc01-06.doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.