My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1434
>
2300 - Underground Storage Tank Program
>
PR0231465
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2020 1:53:30 PM
Creation date
7/20/2020 11:29:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231465
PE
2361
FACILITY_ID
FA0003739
FACILITY_NAME
Colonial Energy CE 40134 (DBA Power Mart)
STREET_NUMBER
1434
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1434 W Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
186
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WALTON <br />ENGINEERING, INC. <br />Overfill Prevention Inspection - OPW 61 and 71 Series Devices <br />Date: 10/12/2018 <br />Owner: <br />Facility: Colonial Energy # 40134 <br />OPW Overfill Model Number: diesel= 61 so <br />Part 1 - Proner Height Setting Calculation <br />Part 2 - Device Certification Criteria Evaluation <br />Does the overfill prevention device meet the 95% <br />requirement? <br />YES <br />Tank 1 <br />Tank 2 <br />Tank 3 <br />Tank 4 <br />Maximum Tank Volume Per: <br />A Gallons <br />8021 <br />more than the fill riser? (J must be 6.5" or more than E) <br />Max shut off requirement for flapper is 95% <br />B 95% <br />95% <br />Does the overfill prevention device function as required? <br />Multiply Max tank volume by 95% <br />C Gallons <br />7620 <br />YES <br />Use tank chart or ATG to determine height of <br />calculated volume <br />D Inches <br />86.375" <br />Measure top of fill riser threads, or face seal <br />adapter <br />E Inches <br />36 1/2" <br />Tank diameter (From Tank Chart) <br />F Inches <br />95 3/4" <br />Upper Tube in Tank (G) F -D = G <br />G Inches <br />9.375" <br />Subtract 2" from upper tube in tank G-2"= K <br />K Inches <br />7.375" <br />Calculated minimum upper tube length (I) <br />K+E=I <br />Roches <br />43.875" <br />Actual measured upper tube length (Without <br />fill adapter) <br />J Inches <br />44 1/4" <br />Part 2 - Device Certification Criteria Evaluation <br />Does the overfill prevention device meet the 95% <br />requirement? <br />YES <br />Is the actual measured upper tube length 6.5 inches or <br />YES <br />more than the fill riser? (J must be 6.5" or more than E) <br />Does the overfill prevention device function as required? <br />(Inspect the device for damage, contamination, freedom of <br />YES <br />movement, weakening due to wear and corrosion <br />Device Overfill Certification PASS / FAIL PASS <br />Drop Tube Testing PASS / FAIL PASS <br />Technician certifies that the device is operationally compliant. <br />Signature of Technician: Date: 10/12/18 <br />Technician's Name: Rey Hernandez <br />
The URL can be used to link to this page
Your browser does not support the video tag.