My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
707
>
2300 - Underground Storage Tank Program
>
PR0505151
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2020 10:31:40 AM
Creation date
7/20/2020 12:53:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0505151
PE
2361
FACILITY_ID
FA0007815
FACILITY_NAME
QUICKI KLEEN CAR WASH
STREET_NUMBER
707
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
707 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN 10 A Q U I N Environmental Health Department <br /> C_ 1_1 i :v Y <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> QUICKI KLEEN CAR WASH 707 E YOSEMITE AVE, MANTECA October 25, 2018 <br /> Item N Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Facility Operating Permit Application and UST Tank Information are not current in CERS. The form list Elena <br /> Manzo as the environmental contact. <br /> UST Tank Information forms for all three tanks are not current in CERS. <br /> -On all three tanks under Vent,Vapor Recovery(VR)and Riser/Fill Pipe Piping Constructio it states primary <br /> containment to be steel and secondary containment for vent to be fiberglass. <br /> -For the 87 product tanks, it states that Vapor recovery primary is steel and secondary as fiberglass however single <br /> wall fiberglass vapor recovery was pipes were observed during the inspection. <br /> Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br /> update the required information,and submit for review by the EHD. <br /> This is a repeat violation, Class II. <br /> 105 CCR 2632(d)(1),2634(d) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. Under record keeping it list"Tank Integrity <br /> Testing Results"however in the DO reports it states that the facility does not perform tank integrity testing. The <br /> monitoring plan must be uploaded to the California Environmental Reporting System(CERS). Immediately log into <br /> CERS, make the necessary changes,and submit for review by the EHD. <br /> This is a minor violation. <br /> 113 CCR 2638(c),2638(d) Failure to submit"Monitoring System Certification Form"within 30 days of completion of the <br /> test. <br /> Annual monitoring system certification, leak detector testing,and spill container testing was performed on 10/09/17 <br /> and a test report was submitted on 4/24/18,five months late. A copy of the test report must be submitted within 30 <br /> days of the tests. Take all necessary precautions to ensure testing and submittal of test reports are performed in a <br /> timely manner. <br /> This is a Class 11 violation. <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on 10/09/17 and an inspection report was issued identifying information to be submitted <br /> to bring this site into compliance. This information was required to be submitted by 11/08/17.This information was <br /> received on 5/31/18,6 months late, resulting in a non-compliant status for this facility. An operator that receives an <br /> inspection report shall have 30 days to submit a written response that includes a statement documenting corrective <br /> actions taken or proposing corrective actions which will be taken. Ensure that a written response documenting <br /> corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. <br /> This is a repeat violation,Class It. <br /> FA0007815 PRO505151 SCO01 10/25/2018 <br /> EHD 23-01 Rev.09/28/2018 Page 4 of 6 Underground Storage Tank Program OR <br /> 1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-34201 F 209 4640138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.