My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4747
>
2300 - Underground Storage Tank Program
>
PR0232482
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2020 2:04:15 PM
Creation date
7/20/2020 1:37:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0232482
PE
2361
FACILITY_ID
FA0003719
FACILITY_NAME
WEST LANE CHEVRON
STREET_NUMBER
4747
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
10437010
CURRENT_STATUS
01
SITE_LOCATION
4747 WEST LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UST THERMOMETER TEST (cont.) <br /> UST#3 7.3.3 <br /> T5 temperature 79.312 <br /> T4 temperature 78.955 <br /> Difference between T5 and T4 temperatures 0.357 <br /> Is the difference less than 10°F?If not,proceed to section 9.1 Yes <br /> 9.1 <br /> T5 temperature <br /> Calibrated thermometer ambient temperature <br /> Difference between T5 and calibrated thermometer <br /> Is the difference less than 10°F? If not,the T5 thermometer does not meet specifications <br /> UST#4 7.3.3 <br /> T5 temperature N / A <br /> T4 temperature <br /> Difference between T5 and T4 temperatures <br /> Is the difference less than 10°F? If not,proceed to section 9.1 <br /> 9.1 <br /> T5 temperature <br /> Calibrated thermometer ambient temperature <br /> Difference between T5 and calibrated thermometer <br /> Is the difference less than 10°F?If not,the T5 thermometer does not meet specifications <br /> ATMOSPHERIC PRESSURE SENSOR TEST <br /> Atmospheric pressure sensor reading(psi) -0.046 <br /> Atmospheric pressure sensor reading(in.mercury) 29.83 <br /> Atmospheric pressure from local source(in.mercury) 29.91 <br /> Difference between local source and pressure sensor reading(A) 0.08 <br /> 0.10 x local source(B) 2.98 <br /> Is A<B?If not,the vapor polisher is not is compliance Yes <br /> NOTES: 'Conversion from pressure(psi)to pressure(in.mercury)is: (psi+14.7)x 2.036 <br /> I declare, under penalty of perjury under the laws of the state of California that based on information and belief formed <br /> after reasonable inquiry, the statements and information provided in this document are true, accurate, and complete. <br /> Signature of Technician: Date: 9/19/2018 <br /> Ver. 1.1—01.20.09 <br />
The URL can be used to link to this page
Your browser does not support the video tag.