4 1
<br /> PQUl,N, SAN JOAQUIN COUNTY
<br /> ENVIRONMENTAL HEALTH DEPARTMENT
<br /> 1868 East Hazelton Avenue, Stockton, CA 95205-6232
<br /> Telephone: (209) 468-3420 Fax: (209) 464-0138 Web:www.sjgov.org/ehd
<br /> �9C%F ORa�P
<br /> NOTICE AND ORDER TO ABATE
<br /> HOUSING AND DANGEROUS BUILDING VIOLATIONS
<br /> San Joaquin County Ordinance Code, Title 8,Division 5
<br /> LOCATION: "C1 CS �% J'6 L lvt� POSTING DATE: &(/c� I
<br /> CITY: �/TCl(KTj0 TYPE OF PREMISE: -f, -C APN:
<br /> OWNER NAME: i 1146 r l" •� In"1 0 HI C-L IT1(06 1",f M PHONE:
<br /> OWNER ADDRESS: 'rNU T fbX. CITY: j'rhJ AiW),v G-0
<br /> TENANT NAME: PHONE: (vs'h
<br /> LISTED VIOLATIONS:
<br /> Items checked below are violations of the California Health&Safety Code,State Housing Law, Section 17920.3
<br /> K1. Lack of, or improper water closet, lavatory, or bathtub or shower in a dwelling unit(subsection a.1)or per number of guest in a
<br /> hotel(subsection a.2).
<br /> E� 2. Lack of,or improper kitchen sink(subsection a.3).
<br /> ❑ 3. Lack of hot and cold running water to plumbing fixtures in a dwelling unit(subsection a.5)or in a hotel (subsection a.4).
<br /> 4. Lack of adequate heating (subsection a.6).
<br /> ❑ 5. Lack of or improper operation of required ventilating equipment(subsection a.7).
<br /> ❑ 6. Lack of minimum amounts of natural light and ventilation required by this code(subsection a.8).
<br /> ❑ 7. Room and space dimensions less than required by this code(subsection a.9).
<br /> 8. Lack of required electrical lighting (subsection a.10).
<br /> ❑ 9. Dampness of habitable rooms(subsection a.11).
<br /> ❑ 10. Infestation of insects,vermin,or rodents (subsection a.12)
<br /> 11. General dilapidation or improper maintenance(subsection a.13.).
<br /> ❑ 12. Lack of connection to required sewage disposal system (subsection a.14).
<br /> 13. Lack of adequate garbage and rubbish storage and removal facilities(subsection a.15).
<br /> 14. Other unsanitary conditions (subsection a).
<br /> ❑ 15. Deteriorated or inadequate foundations(subsection b.1).
<br /> Defective or deteriorated flooring or floor supports(subsection b.2)or of insufficient size to carry imposed loads with safety
<br /> ❑ 16. (subsection b.3).
<br /> 5Cf'JJC,0
<br /> 17. Members of walls, partitions, or other vertical supports that split, lean, list,or buckle due to defective material or deterioration
<br /> (subs- or of insufficient size to carry imposed loads with safety(subsection b.5).
<br /> ❑ 18. Members of ceilings, roofs, ceilings and roofs supports, or other horizontal members which sag,split, or buckle due to defective
<br /> material or deterioration (subsection b.6)or of insufficient size to carry imposed load with safety(subsection b.7).
<br /> ❑ 19. Fireplaces or chimneys,which list, bulge, or settle due to defective material or deterioration(subsection b.8)or of insufficient size
<br /> or strength to carry imposed loads with safety(subsection b.9).
<br /> ❑ 20. Other structural hazards(subsection b).
<br /> ❑ 21. Any nuisance (subsection c).
<br /> z2. Hazardous or inadequate wiring (subsection d).
<br /> 23. Hazardous or inadequate plumbing (subsection e).
<br /> 24. Hazardous or inadequate mechanical (subsection f).
<br /> 25. Deteriorated, crumbling, or loose plaster(subsection g.1).
<br /> W26. Deteriorated or ineffective waterproofing of exterior walls, roof,foundations, or floors, including r doors
<br /> (subsection g.2)or lack of paint or other protective covering(subsection g.3).
<br /> ❑ 27. Broken, rotted, split,or buckled exterior wall coverings or roof coverings(subsection g.4).
<br /> ❑ 28, Fire hazard (subsection h).
<br /> � g. Materials of construction are inadequate or hazardous (subsection 1).30 . Accumulation of weeds,vegetation,junk,dead organic matter, debris,garbage,offal, rodent harborages, stagnant water,
<br /> combustible materials, and similar materials or conditions constitutes fire, health, or safety hazards(subsection j).
<br /> K31. Unsafe building due to inadequate maintenance(subsection k). A,J fcL."'n
<br /> ❑ 32. Inadequate exits(subsection 1).
<br /> ❑ 33. Lack of or improper fire-resistive construction or fire-extinguishing systems or equipment(subsection m).
<br /> ❑ 34. Improper occupancy(subsection n).
<br /> ❑ 35. Inadequate structural resistance to horizontal forces (subsection o).
<br /> ❑ 36. Premise/building contains a"Lead Hazard (Section 17920.10)
<br /> ALL VIOLATIONS MUST BE CORRECTED WITHIN 30 DAYS OF NOTIFICATION - UNLESS OTHERWISE SP IED BELOW
<br /> Failure to compiy by the compiiance date wiii resuit in file cosi recovery of all EHD staff time at a rate of$12' per hour.
<br /> ❑ EMERGENCY ABATEMENT ORDER ISSUED(Section 8-5200) ❑ COMPLIANCE DATE l'Z f"0/0
<br /> Emergency Conditions to be Abated:
<br /> MP RTANT NOTES:
<br /> Vacant structure must remain vacant until approved by the Environmental Health Department.
<br /> Repair or demolition permits must be obtained from the San Joaquin County Building Division prior to rehabilitation/demolition.
<br /> ❑ Septic and/or well permits must be obtained from the San Joaquin County Environmental Wealth Repartment.
<br /> UNSAFE TO OCCUPY Date to be Vacated: d' 'JZ
<br /> STRUCTURE(S)HAS BEEN DETERMINED TO BE UNSAFE TO OCCUPY PURSUANT TO THE UNIFORM CODE FOR THE ABATEMENT OF DANGEROUS BUILDINGS,SECTION 4048
<br /> STRUCTURES MAY NOT BE REOCCUPIED WITHOUT APPROVAL OF THE ENVIRONMENTAL HEALTH DEPARTMENT
<br /> REMARKS: ),/ L / l/%9 7' 74)T 1 7, 7737.J
<br /> Inspected/Posted By: Phone:
<br /> Lyn,ro ental Health Specialist
<br /> Received By: U ❑Owner ❑Tenant Phone:
<br /> 4
<br /> The reverse side of this sheet contains information and requirements necessary to comply with this NOTICE AND ORDER
<br /> EHD 13-03 4/30/12 NOTICE&ORDER TO ABATE
<br />
|