Laserfiche WebLink
110 2nd Avenue South,#D7 Pacheco CA 94553-5560 <br /> McCampbell Analytical Inc I Telephone 925-798-1620 Fax 925-798-1622 <br />' http!/www mccampbell com E mail rmun@mccampbell com <br /> QC SUMMARY REPORT FOR SW8015C <br /> Matnx W WorkOrder 0303082 <br /> EPA Method SW8015C Extraction SW3510C BatchlD 6080 Spiked Sample ID N/A <br /> Compound <br /> Sample Spiked MS' MSO" MS-MSD' LCS LCSD LCS-LCSD Acceptance Criteria(%) <br />' fig/L pg/L % Rea %Rec % RPD %Rec %RPD Low Nigh <br /> TPH(d) N/A 7500 N/A N/A NIA 105 104 0 379 70 130 <br />' %SS N/A 100 NIA NIA NIA 96 4 95 5 0$95 70 130 <br /> All target compounds in the Method Blank of this extraction batch were AID less than the method RL with the following exceptions <br /> NONE <br /> 1 <br /> I <br /> MS=Matrix Spike MSD=Matrix Spike Duplicate,LCS=Laboratory Control Sample LCSD=Laboratory Control Sample Duplicate RPD=relative Percent <br /> Deviation <br /> N/A=not enough sample to perform matrix spike and matrix spike duplicate <br /> NR=analyte concentration in sample exceeds spike amount for soil matrix or exceeds 2x spike amount for water matrix or sample diluted due to high matrix or <br /> analyte content <br /> %Recovery=100.(MS-Sample)/(Amount Spiked) RPD=100"(MS—MSD)/(MS+MSD)*2 <br /> 'MS and/or MSD spike recovenes may not be near 100%or the RPDs near 0%if a)the sample is inhomogenous AND contains significant concentrations of <br /> analyte relative to the amount spiked or b)if that specific sample matrix Interferes with spike recovery <br /> l <br />