Laserfiche WebLink
'• Quarterly Report - Thi <br /> rd Quarter 2003 <br />' M.ANTECA CITY CORPORATION YARD <br /> 210 East Wetmore Street, Manteca, California <br />' 1.0. INTRODUCTION <br />' At the request of Mr Frederic Clark of the City of Manteca, Advanced GeoEnvironmental, Inc <br /> (AGE) has prepared this quarterly report for the property located at 210 East Wetmore Street, <br /> Manteca, California The site and the surrounding area are illustrated on Figure 1 Structures and <br />' well locations are illustrated on Figure 2 <br />' 2.0. PROCEDURES <br /> Ten ground water monitoring wells (MW I through MW 10) were monitored and sampled on 12 <br />' August 2003 Field work was performed in accordance with guidelines issued by the Central Valley <br /> Regional Water Quality Control Board (CVRWQCB) for the investigation of underground storage <br /> tank(UST) sites <br /> 1 <br />' 2 1 WELL MONITORING AND PURGING <br /> On 12 August 2003, the depth to ground water in all ten monitoring wells was measured from the <br />' top of each well casing to the nearest 0 01-foot utilizing a Solinst water level meter Ground water <br /> elevation in each well was calculated by subtracting the measured depth to ground water from the <br /> surveyed casing elevation (Table 1) <br /> After water levels were measured, between 4 0 and 4 5 gallons of water (a minimum of 3 casing- <br /> water volumes per well)were purged from monitoring wells MW 1 through MW 10 using dedicated, <br /> disposable plastic bailers Groundwater temperature,pH and conductivity were measured at regular <br /> intervals during purging using an Oakton water analyzer Field sheets and data are included in <br /> Appendix A Purged water was stored in properly labeled DOT-approved 55-gallon drums and stored <br /> on-site <br /> I22 COLLECTION OF GROUND WATER SAMPLES <br /> Water samples were collected from each purged well using new disposable plastic bailers after <br /> allowing the wells to achieve a minimum 80%recovery of the pre-purge water volume Each water <br /> sample was transferred into one I-liter amber bottle without sample preservative and into three <br /> 40-m1 volatile organic analysis (VOA) vials containing 0 5 ml IS% hydrochloric acid as a sample <br /> preservative Aber collection, the samples were properly labeled, placed in a chilled container and <br /> transported under chain-of-custody to McCampbell Analytical,Inc (MAI),a California Department <br /> of Health Services-certified analytical laboratory, for analysis The samples were analyzed for <br /> Advanced GeoEnvironmental,Inc <br />