Site Number l� l �� Date <br /> B/►SEItAENT SUREY rfthereris.no basemen legve Ispac <br /> le blank r " <br /> Do the UST's have water-tight sumps to capture and contain any releases? <br /> (visually verified) <br /> Do UDCs have UDC sensors tied into the TLS? <br /> Are the UST High Level Alarms set at 95%and Max Level Alarms set at 100%in <br /> the TLS?Is there a visual/audible overfill alarm at the tank pad and an audible <br /> overfill alarm set on the TLS? <br /> Are the storm drains in front of the C-store clear of debris and do they carry away <br /> liquids to prevent pooling? <br /> Has the site drainage system been modified in the past 12 months? _ <br /> Have any new structures or equipment been added/installed within 10 m of the <br /> basement walls? <br /> Is there any bulk storage of chemicals or products in the basement? ii- J 2 U I G <br /> Are service entries in basement walls adjacent to forecourt areas fully sealed with <br /> no visible ground water ingress i::N\11R[")N N1 ENTAL <br /> Do Electrical conduit/ducts from the forecourt area enter the c store building <br /> above ground,or provisions shall be provided for an intermediate containment <br /> If basement is NOT normally vented to atmosphere(closed walls and ceiling)then <br /> is there a forced ventilation system that starts if the LEL limits are reached. <br /> Is the tank pad surface in good/tight condition?Pad should be liquid tight <br /> paving/concrete to prevent spilled fuel from migrating through soil and into the <br /> basement <br /> Are all rooms in basement open for shared ventilation? <br /> Are emergency lights EX Rated? <br /> Does the basements have Flammable Gas Detection systems:With functioning <br /> audible and visual alarm indication? <br /> 1 st Alarm Point set at 20%LEL:Triggers evacuation of any occupants in <br /> basement and investigation of the alarm source <br /> 2nd Alarm Point set at 40%LEL:Triggers Emergency Shutdown(ESD)of all <br /> electrical equipment in the basement area,a complete shutdown of the forecourt <br /> el system,and evacuation of the site. <br /> Verify the Detectors are: <br /> -located in areas of potential ingress of vapors&close to floor level <br /> (usually 10-24 inches above floor) <br /> -linked to a visual&audible alarm located in the basement and at a <br /> manned location on sites(e.g.Cashier station) <br /> Does the CStore have signs posted with instructions to attendants on what to do <br /> n case of LEL Alarm? <br /> Are sources of ignition in basement either be isolated by and Emergency <br /> Shutdown or shall be removed from basement areas? <br /> Are all non-essential electrical equipment by automatically isolated by the ESD? <br /> Are there any gas-fired equipment with pilot lights? <br /> Is essential electrical equipment-gas detection,emergency lighting and any <br /> ventilation must be EX rated for use in potentially explosive atmospheres? <br /> Is all other non-rated equipment removed or tied into the shut-down on ESD,this <br /> includes: <br /> -Gas and electric heating and ventilating equipment <br /> -Incoming electrical main switches,fuses and meters <br /> -Electrical control or switch panels <br /> -Electrical(mains,battery),gas/diesel powered motors for generators or <br /> compressors <br /> -Standby power battery packs <br /> Have the detectors been tested per manufacturers guidance by a certified <br /> Technician and did everything pass or were repairs made?Where are the <br /> inspection records retained? <br /> Has testing confirmed that Emergency Lighting works are required and non- <br /> Essential ignition sources tum off? <br /> In the past 12 months,has there been any instances of the LEL Detector <br /> activating either due to actual release or false alarm? <br /> Is there any other indication(stain,odor,damage to equipment,etc.)in the <br /> basement that hydrocarbons may or could be accumulating in the basement? <br /> +slued 12/272017 Page 9 of 10 <br />