My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0011973
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
130
>
3500 - Local Oversight Program
>
PR0545892
>
ARCHIVED REPORTS_XR0011973
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2020 2:50:46 PM
Creation date
7/22/2020 2:22:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0011973
RECORD_ID
PR0545892
PE
3528
FACILITY_ID
FA0003601
FACILITY_NAME
ARCO STATION #826951*
STREET_NUMBER
130
Direction
S
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205-5561
APN
15502064
CURRENT_STATUS
02
SITE_LOCATION
130 S WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLES <br /> Analytical Parameter Summary <br /> ARCO Service Station No 5469 <br /> 130 South Wilson Way,Stockton,California <br /> Distance to Ferrous Total Heterotrophic Nitrate Sulfate Sulfite Phosphate <br /> Well nearest COD I DO 2 ORP3 iron 4 iron 5 plate count 6 TOC 7 as NO,' as SO4 a as SO,' (Ortho)as P e TDS <br /> Number Date injection well m m m m CPU/ml m m m m m m <br /> NOTES <br /> COD was analyzed using EPA Method 410 4 µgR.=micrograms per liter QA/QC Review <br /> Z Dissolved oxygen(DO)was analyzed using EPA Method 360 1 NA=Not analyzed A Data accrptcd without qualification <br /> 'Oxidation reduction potential(ORP)was analyzed using ASTM D1498 76 I=Data accepted with qualification <br /> °Ferms iron was analyzed using Hach Method 8146 NS—Not sampled R=Data rejected <br /> 5 Total iron was analyzed using EPA Method 200 7 NP T Not Purged <br /> 6 Heterutrophic plate count was conducted using SM 9215 B <—Below detection liimt for the analytical methods used <br /> 7 Total organic carbon was analyzed using EPA Method 415 1 <br /> a Nitrite,nitrate sulfates and phosphates were analyzed using EPA Method 300 0 <br /> 9 Sulfite was analyzed using EPA Method 377 t <br /> 10 Total alkalinity was analyzed using SM 2320E <br /> Total solids were analyzed using EPA Method 160 t <br /> ]1]The sample was analyzed beyond the EPA recommended holding time <br /> f2]The incubation was performed at 35 degrees C for 48 hours with plate count agar <br /> ]3]The sample was received beyond the EPA recommended holding time <br /> 141 This sample was analyzed beyond the EPA recommend hold time(8 firs) The sample was kept on ice at 5 degrees C and analyzed within 24 hours of sample collection <br /> 151 This sample was prepared outside the 8 hour recommended holding time for this analysts <br /> 16]Sample result may be biased high Matric spike and matrix spike duplicate recoveries exceed upper control limits <br /> ]7]Sample result maybe biased low Matnx spike duplicate recovery exceeds lower control limit Matrix spike recovery was within control limits <br /> [8]Reported results may be biased low since the analyses for these analytes were perfomied beyond the US EPA recommended holding time <br /> [9]The method blank contains this analyte at a concentration above the reporting limit however the concentration is less than 5%of the sample result which is negligible according to method criteria <br /> [10]The reporting limit for this analyte has been raised to account for matrix interference <br /> [111 The concentration indicated for this analyte is an estimated value above the calibration range of the instrument <br /> [12]Confirmatory analysts was past EPA recommended holding time <br /> 1[131 This sample was originally analyzed within the EPA recommended hold time Re-analysis for confirmation or dilutton was performed past the recommended hold time The result from the initial analyses are reported in the Table <br /> 1141 Repotted results may be biased high since the analyses for these analytes were performed beyond the US EPA recommended holding time <br /> [151 Reported result should be considered estimated since the analyses were performed beyond the US EPA recommended holding time <br /> 116]Reported result may be biased low as indicated by a low average percent matrix spike recovery reported in the associated MSIMSD analysis <br /> [17]The reported result may be eshmaled since the analyses for these analytes were performed beyond the USEPA recommended holding time <br /> [18)The reported result may be biased since the analyses for these analytes were performed beyond the US EPA recommended holding time <br /> [19]The reported result should he considered estimated due to a high relative percent dtfference reported between the primary and laboratory duplicate samples <br /> 120]Analyte present to the method blank <br /> STRATUS <br /> Arco-5469-0&M_Data <br /> 6of6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.