My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0011996
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
130
>
3500 - Local Oversight Program
>
PR0545892
>
ARCHIVED REPORTS_XR0011996
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2020 2:52:26 PM
Creation date
7/22/2020 2:36:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0011996
RECORD_ID
PR0545892
PE
3528
FACILITY_ID
FA0003601
FACILITY_NAME
ARCO STATION #826951*
STREET_NUMBER
130
Direction
S
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205-5561
APN
15502064
CURRENT_STATUS
02
SITE_LOCATION
130 S WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE 1 <br /> GROUNDWATER ELEVATION AND ANALYTICAL SUMMARY <br /> ARCO Service Station No.5469 <br /> 130 South Wilson Way,Stockton,California <br /> Elevation Top of Well Static Water Groundwater Groundwater Ethyl- Total <br /> Well Top of Casing Screen level Elevation Flow GRO+ Benzene Toluene benzene Xylenes MTBE[1] <br /> Number Date feet ms]) feet b feet b s feet msl Direction µ <br /> NOTES: <br /> +=Results through the first quarter 2004 include purgeable hydrocarbons in the range of C6-C10. GRO-Gasoline Range Organics QAIQC Review: <br /> GRO analyzed using EPA Method 801513. All other analytes analyzed using EPA Method 8260B. MTBE=Methyl tert-butyl ether A=Data accepted without qualification <br /> [t]MTBE was analyzed using USEPA Method 8020. NA=Not analyzed J Data accepted with qualification <br /> [2]MTBE was analyzed using USEPA Method 8260. NC=Not calculated R=Data rejected <br /> [3]The value reported exceeds the calibration curve,but not the linear range. NS=Not sampled <br /> [4]Chromatogram Pattern: Weathered Gasoline C6-C 12. rust=mean sea level <br /> [5]The reporting limits for this sample have been raised due to the high level of a target compound. bgs=below ground surface <br /> [6]The reporting Iimit(s)for this sample have been raised due to high levels of non-target inteferents. µg11.=micrograms per liter <br /> [7]Sample was diluted due to high levels of Benzene. <=Below detection limit for the analytical methods used. <br /> [8]Hydrocarbon pattern is present in the requested fuel quantitation range but does not resemble the pattern of the requested fuel. <br /> [9]Sample was reanalyzed past EPA recommended holding time. <br /> [10]The sample was diluted due to the presence of high levels of target analytes resulting in elevated reporting limits <br /> [I I]Laboratory report indicates discrete peak at MTBE and Benzene. <br /> [121 Labomfory report indicates discrete peak at MTBE. <br /> [131 The concentration indicated for this analyte is an estimated value above the calibration range of the instrument. <br /> [141 This sample was analyzed beyond the EPA recommended holding time. <br /> [15]Based on notes in laboratory report and conversation with laboratory(11119102),this TPHG result is due entirely to presence of MTBE. No other compounds eluted in the TPHG range. (Refer to Stratus' <br /> Quarterly Groundivater Monitoring Report, Third Quarter 2002, dated November 20,2002). <br /> [16]The continuing calibration standard was outside of the acceptance criteria. <br /> [17]The sample was diluted due to the presence of high levels of non-target analytes resulting in elevated reporting limits. <br /> [I S]Discrete peak @ C6-C7. <br /> [19]Reported result is due to a discrete peak at C5 and has been rejected. <br /> [20]Analyte was also reported in the associated laboratory blank as well as in the sample. Result should be considered not detected. <br /> [21]Initial results may be biased high as shown by surrogate recoveries above method acceptance limits(due to matrix interference). Sample re-analyzed outside of EPA recommended hold time. Initial result reported in the table,and <br /> should be considered an estimate. <br /> [22]Initial result was an estimate,beyond the calibration range of the instrument. Sample re-analyzed beyond the EPA recommended hold time. Initial result reported in the table. <br /> [23]The reported results may be biased low since the analyses for these analytes were performed beyond the EPA recommended holding time of 14 days. <br /> [24]The reported results may be biased low as demonstrated by a low surrogate recovery due to matrix interference. <br /> [251 Initial result not confirmed by re-analysis. Re-analysis performed beyond hold time. Initial result reported in the table,should be considered an estimate. <br /> [26]The reported result may be biased low as demonstrated by a low surrogate recovery. <br /> [271 Discrete peak @ C5. <br /> S7lZATUS <br /> Arco 5469 Quarterly_Data <br /> 9of9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.