TABLE 5 <br /> Analytical Parameter Summary <br /> ARCO Service Station No.5469 <br /> 130 South Wilson Way, Stockton,California <br /> Distance to FerrousTotal Heterotrophic Nitrate Sulfate Sulfite Phosphate <br /> Well nearest COD' DO' ORP3 iron° irons plate count 6 TOC' as NO,' as SO4 a :aS S03 9 (Ortho)as P e TDS t <br /> Number Date mtCFUhnI m m m in m m <br /> NOTES: <br /> I COD was analyzed using EPA Method 410.4 Wt.=micrograms per liter QA/QC Review: <br /> 2 Dissolved oxygen(DO)was analyzed using EPA Method 360.1 NA=Not analyzed A=Data accepted without qualification <br /> 3 Oxidation reduction potential(ORP)was analyzed using ASTM D 1498-76 7 w Data accepted with qualification <br /> 4 Ferros iron was analyzed using Hach Method 8146 NS=Not sampled R=Data rejected <br /> s Total'iron was analyzed using EPA Method 200.7 NP=Not Purged <br /> a Heterotrophic plate count was conducted using SM 9215 B c=Below detection limit for the analytical methods used. <br /> 7 Total organic carbon was analyzed using EPA Method 415.1 <br /> a Nitrite,nitrate,sulfates and phosphates were analyzed using EPA Method 300.0 <br /> 9 Sulfite was analyzed using EPA Method 377.1 <br /> 10 Total alkalinity was analyzed using SM 2320E <br /> r t Total solids were analyzed using EPA Method 160.1 <br /> [ <br /> 11 The sample was analyzed beyond the EPA recommended holding time. <br /> f21 The incubation was performed at 35 degrees C for 48 hours with plate count agar <br /> [31 The sample was received beyond the EPA recommended holding time. <br /> [41 This sample was analyzed beyond the EPA recommend hold time(S his). The sample was kept on ice at 5 degrees C and analyzed within 24 hours of sample collection. <br /> [5]This sample was prepared outside the 8 hour recommended holding time for this analysis. <br /> [6]Sample result may be biased high. Matric spike and matrix spike duplicate recoveries exceed upper control limits. <br /> 171 Sample result may be biased low. Matrix spike duplicate recovery exceeds lower control limit. Matrix spike recovery was within control limits. <br /> 181 Reported results may he biased low since the analyses for these analytes were performed beyond the US EPA recommended holding time. <br /> [9]The method blank contains this analyte at a concentration above the reporting limit;however,the concentration is less than 5%of the sample result,which is negligible according to method criteria. <br /> [101 The repotting limit for this analyte has been raised to account for matrix interference. <br /> [l It The concentration indicated for this analyte is an estimated value above the calibration range of the instrument. <br /> [12]Confirmatory analysis was past EPA recommended holding time. <br /> [13]This sample was originally analyzed within the EPA recommended hold time. Re-analysis for confirmation or dilution was perforated past the recommended hold time. The result from the initial analyses are reported in the Table. <br /> [14]Reported results maybe biased high since the analyses for these analytes were performed beyond the US EPA recommended holding time. <br /> 151 Reported result should be considered estimated since the analyses were performed beyond the US EPA recommended holding time. <br /> 1 161 Reported result may be biased low as indicated by a low average percent matrix spike recovery reported in the associated MS/MSD analysis. <br /> 5TRAW6 <br /> Arco 5469 0&M_Dats <br /> 5of5 <br />