My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0011996
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
130
>
3500 - Local Oversight Program
>
PR0545892
>
ARCHIVED REPORTS_XR0011996
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2020 2:52:26 PM
Creation date
7/22/2020 2:36:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0011996
RECORD_ID
PR0545892
PE
3528
FACILITY_ID
FA0003601
FACILITY_NAME
ARCO STATION #826951*
STREET_NUMBER
130
Direction
S
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205-5561
APN
15502064
CURRENT_STATUS
02
SITE_LOCATION
130 S WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 <br /> 4 <br /> 1455 McDowell Blvd,North Ste D <br /> Sequoia Petaluma,CA 94954 <br /> AA . (707)792-1865 <br /> nAytical. FAX(707)792-0342 <br /> M <br /> www.sequoialabs.com <br /> URS Corp-Sacramento Project: Arco Site 5469,Stockton,CA P406178 <br /> 2870 Gateway Oaks Drive Suite 300 Project Number: MW6605 Reported: <br /> Sacramento CA,95833 Project Manager: Jay Johnson 06/30/04 13:08 <br /> Notes and Definitions <br /> E The concentration indicated for this analyte is an estimated value above the calibration range of the instrument. <br /> HC-19 Discrete peak @ C5. <br /> HT-01 This sample was received beyond the EPA recommended holding time.The results may still be useful for their intended purpose. <br /> HT-RA This sample was originally analyzed within the EPA recommended hold time. Re-analysis for confirmation or dilution was <br /> performed past the recommended hold time. The results may still be used for their intended purpose. <br /> QC01 The percent recovery was above the control limits.The sample results may still be useful for their intended purpose. <br /> QC20 The RPD was outside control limits.The results may still be useful for their intended purpose. <br /> QC21 The RPD result exceeded the control limits;however,both percent recoveries were acceptable.Sample results for the QC batch <br /> were accepted based on percent recoveries and completeness of QC data. <br /> QMO l The spike recovery was above control limits for the MS and/or MSD. The batch was accepted based on acceptable LCS recovery. <br /> QM02 The spike recovery was below control limits for the MS and/or MSD. The batch was accepted based on acceptable LCS recovery. <br /> QM05 The spike recovery was below control limits for the MS and/or MSD due to analyte concentration at 4 times or greater the spike <br /> concentration.The QC batch was accepted based on LCS and/or LCSD recoveries within the acceptance limits. <br /> DET Analyte DETECTED <br /> ND Analyte NOT DETECTED at or above the reporting limit or MDL,if MDL is specified <br /> NR Not Reported <br /> i <br /> dry Sample results reported on a dry weight basis <br /> j RPD Relative Percent Difference <br /> i <br /> i <br /> I <br /> I <br /> I <br /> i <br /> j Sequoia Analytical-Petaluma The results in this report apply to the samples analyzed in accordance with the <br /> chain of custody document, Unless otherwise stated,results are reported on a wet <br /> weight basis. This analytical report must be reproduced in its entirety. <br /> i; <br /> I'. <br /> I' <br />{ Page 36 of 37 <br /> d <br /> .:�.�,..�.�:.:�..._._.,�... Wim,. W_ ... -. .. . .. <br />
The URL can be used to link to this page
Your browser does not support the video tag.