Laserfiche WebLink
S 11�1 N J OAQ I I N Environmental Health Department <br /> COUNTY— AMENDED <br /> 11/25/2019 <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GOLDEN STATE LUMBER INC 3033 S Airport Way, Stockton November 22, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 601 CCR 66262.34(d)Stored hazardous waste onsite greater than 180 days. <br /> OBSERVATION: The following hazardous waste container was found on-site with a hazardous waste label missing <br /> the accumulation start date: <br /> In the maintenance shop, one blue 55 gallon steel drum containing used antifreeze(full). <br /> REGULATION GUIDANCE: <br /> (a)Except as provided in subsections(c)and (d)of this section and section 66262.35, a generator may accumulate <br /> hazardous waste on-site for 90 days or less without a permit or grant of interim status, provided that: <br /> (b)The beginning of the 90 day period specified in subsections(a)and (c)of this section is determined as follows: <br /> (1)if the generator does not generate more than 100 kilograms of hazardous waste or one kilogram of acutely <br /> hazardous waste(listed in section 66261.33(e))or one kilogram of extremely hazardous waste during any calendar <br /> month,the 90 day period begins on the date the generator has accumulated 100 kilograms of hazardous waste or <br /> one kilogram of acutely hazardous waste or one kilogram of extremely hazardous waste; <br /> (2)if the generator generates more than 100 kilograms of hazardous waste or one kilogram of acutely hazardous <br /> waste or one kilogram of extremely hazardous waste during any calendar month,the 90-day period begins on the <br /> first date on which any amount of hazardous waste begins to accumulate during that month. <br /> (d)Notwithstanding subsections(a)and (c)of this section and section 66262.35, a generator of less than 1,000 <br /> kilograms of hazardous waste in any calendar month who accumulates hazardous waste onsite for 180 days or <br /> less, or 270 days or less if the generator transports the generator's own waste, or offers the generator's waste for <br /> transportation, over a distance of 200 miles or more,for offsite treatment,storage, or disposal, is not a storage <br /> facility if all of the following apply: <br /> (1)The quantity of hazardous waste accumulated onsite never exceeds 6,000 kilograms. <br /> (2)The generator complies with the requirements of 40 Code of Federal Regulations section 262.34(d), (e)and (f). <br /> (3)The generator does not hold acutely hazardous waste or extremely hazardous waste in an amount greater than <br /> one kilogram for more than 90 days. <br /> CORRECTIVE ACTION: Immediately dispose of the hazardous waste stored on site greater than 180 days in <br /> compliance with Title 22 California Code of Regulations. Provide a corrective action statement and a copy of the <br /> disposal records to the San Joaquin County Environmental Health Department(EHD)within 30 days. <br /> This is a Class II violation. <br /> FA0015541 PR0538493 SCO01 11/22/2019 <br /> EHD 22-01 Rev.9/20/2019 Page 12 of 16 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />