Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br /> Type of Action ❑ Installation Inspection ❑Repair Inspection ❑x 36 Month Inspection <br /> I. FACILITY INFORMATION <br /> CERS ID 10181407 Date of Overfill Prevention Equipment Inspection <br /> 04/17/2019 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> Kwik Sery#113 <br /> Business Site Address City ZIP Code <br /> 420 W. Kettleman Lane Lodi 95240 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection(Print as shown on the ICC Certification.) Phone# <br /> Steven White (408)971-2445 <br /> Contractor!Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 485184 8898679 05/10/20 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> 1016243710 <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ® Manufacturer Guidelineseci S( p �) OPW Manual <br /> Used: <br /> ❑ Industry Code or Engineering Standard(Specify): <br /> ❑ Engineered Method (Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. #of Attached Pages <br /> TANK ID: (By tank number, stored product.etc.) 87 91 Diesel E85 <br /> What is the tank inside diameter?(Inches) 120 120 120 120 <br /> Is the fill piping secondarily contained? ❑ Yes ✓❑ No ❑Yes © No ❑Yes © No ❑Yes ✓❑ No <br /> Is the vent piping secondarily contained? ❑Yes © No ❑Yes ❑✓ No ❑Yes ® No ❑Yes © No <br /> Overfill Prevention Equipment Manufacturer(s) OPW OPW OPW OPW <br /> What is the overfill prevention equipment response ❑ Shuts Off Flow ❑Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow <br /> when activated? <br /> (Check all that apply.) ®Restricts Flow ®Restricts Flow ® Restricts Flow ® Restricts Flow <br /> ❑AN Alarm ❑AN Alarm ❑AN Alarm ❑AN Alarm <br /> Are flow restrictors installed on vent piping? ❑Yes ❑✓ No ❑Yes ❑✓ No ❑Yes ® No ❑Yes ®No <br /> At what level in the tank is the overfill prevention set <br /> to activate?(Inches from bottom of tank.) <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? <br /> Is the overfill prevention in proper operating condition ❑Yes ❑Yes ❑Yes ❑Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑ No(Specify in V.) ❑ No(Specify in V) ❑ No(Specify in V.) ❑ No(Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ❑ Pass ❑x Fail 11 ❑ Pass ❑x Fail 11 ❑ Pass ❑x Fail ❑ Pass E Fail <br /> V. COMMENTS <br /> Any items marked"Fail"must be explained in this section. Any additional comments may also be provided here. <br /> "Could not remove 87,91 and Diesel Drop Tubes due to stuck risers on 87/91 and stuck Adaptor/riser on Diesel.Was able to verify functioning flapper on the E85 but could not locate the <br /> tank chart for that tank. <br /> lviM 9 'i Lj ly <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations,Title 23, <br /> Division 3,Chapter 16,Section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signature -�- `� <br /> If the facility has more components thanthis form�accommodates,additional copies of this page may be attached. <br /> CERS=California Environmental Reporting System.ID=Identification,UST=Underground Storage Tank,ICC=International Code Council,AA/=Audible and Visual <br />