Laserfiche WebLink
SAN J O A Q U I N Environmental Health Department <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name : Facility Address : Date: <br /> EAGLE ROOFING PRODUCTS-STOCKTON 14555 MCKINLEY AVE , STOCKTON August 12 , 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 601 CCR 66262 . 34 (d ) Stored hazardous waste onsite greater than 180 days . <br /> In the hazardous waste storage area , one white 55 gallon steel drum containing used antifreeze had an 11 /13/2018 <br /> accumulation start date . Facilities who generate less than 1000 kg of hazardous waste per month and do not <br /> exceed 6000 kg of waste stored on site at any time may store waste on site up to 180 days . Immediately contact a <br /> licensed hazardous waste hauler to dispose of this waste under manifest and submit a copy of the manifest to the <br /> EHD . <br /> This is a Class II violation . <br /> Overall Inspection Comments : <br /> i <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation , and any supporting <br /> paperwork , by September 11 , 2019 , <br /> Starting September 1 , 2018 , all in -office CERS help will be provided at EHD hourly rate ($ 152 ) . To schedule an <br /> appointment , please call (209 ) 468-3420 . <br /> The following minor violations were corrected during the inspection : <br /> -The contingency plan was missing the contact information for the emergency coordinators , the location of all of <br /> the spill control equipment , the phone number for the fire department, and was not posted . There must be at least <br /> one emergency coordinator on site or on call to coordinate emergency response measures , and the following <br /> information must be posted by a phone : the name and phone number of the emergency coordinator; location of fire <br /> extinguishers , spill control equipment, and if present , fire alarm ; and the phone number of the fire department, <br /> unless the facility has a direct alarm . Immediately appoint an emergency coordinator and post the required <br /> information by a phone . The contingency plan was corrected during the inspection and posted . <br /> - In the hazardous waste storage area : <br /> -One white 55 gallon steel drum containing used antifreeze was observed with a hazardous waste label missing the <br /> hazardous property. <br /> -One black 55 gallon steel drum containing used oil was observed with a hazardous waste label missing the <br /> hazardous property . <br /> -One black 55 gallon steel drum containing used oil was observed with a hazardous waste label missing the <br /> hazardous property and physical state . <br /> All hazardous waste containers shall be marked with the following information : <br /> - the words " Hazardous Waste" <br /> - name and address of generator <br /> - hazardous properties <br /> - physical state <br /> - composition (contents ) <br /> - accumulation start date <br /> FA0015745 PRO538495 SCO01 08/12/2019 <br /> EHD 22-01 Rev. 09/27/2018 Page 5 of 6 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 I F 209 464-0138 1 www. sjcehd . com <br />