Laserfiche WebLink
1 I GIVI ttG 1 J <br /> Secondary Containment <br /> Vacuum Sensing <br /> System <br /> Maximize protection with a vacuum 1 <br /> s <br /> monitored secondary containment <br /> system . <br /> 1 <br /> A Secondary Containment Vacuum Features and Benefits Facilitates periodic operability testing <br /> Sensing System for use with Veeder- Sabsfv Requitements Leverage Existing Veeder-Root Systems 1 <br /> Root's ATG Systems. The Secondary • Cemfred to meet Cahlomia's requirement for . Uses STP as the vacuum sotuce and works with <br /> secondary space monitoring for tants and lines Redacket and FE STPs <br /> Containment Vacuum Sensing (SCVS) as required by AB 2481 <br /> System is designed to detect leaks in double- . Saisfiesthe requirements for(lasIleak consul mthe SIP sump andconnects to the <br /> walled tanks and piping systems while Detection as definedbythe European console viare whin conduilly safe t <br /> iting <br /> with 1 <br /> Standard EN 13160-2 Able r-sltat intrinsically safe <br /> withother <br /> helping to contain a release of product while Uezder-Root inttittadly safe(IS)probes and <br /> National <br /> • 3rd Parry, Work Group and LG 113 under vacuum.The system consists of: listed salons including sump or line leak sensors <br /> • Interfaces to the Smart Sensor Interface with 1 <br /> • Vacuum Sensors, connected to tank, Reduce Exposure to Risk Embedded Pressure Module <br /> Alarms when vacuum carntot be maintained Provides for positive shut down of pressurized <br /> sump or piping interstices lines when required <br /> orwhen replenish rare exceedslitersc pet hour <br /> • A Submersible Turbine Pump(STP), Simple installation no need to mess with brine <br /> • The system alarms when liquid is is detected¢n 1 <br /> to provide a source of vacuum the secondary space <br /> • A Sman Sensor Interface with Embedded <br /> Pressure Module in a TLS-350 Operating Temperature Rating: Console Capability <br /> Monitoring System -25 degrees C to+70 degrees C The Vacuum Sensor is compatible with <br /> the following consoles: 1 <br /> Length: Console <br /> Cable Leng <br /> The Vacuum Sensor is interfaced Veeder- TLS-350l w/BIH' <br /> Root's TLS-350 Monitoring System via e feet TLS-350 Plus/EMC Enhanced' <br /> intrinsically safe wiring to provide system Sensor Dimensions' TLS-350/EMC 1 <br /> status,replenish rate,alarm,and diagnostic 5"high x 5"wide 2"deep 'Upgrade Nola The Vacuum Sensor System requires <br /> the console to have version 240 software(or greater) <br /> information. along with an ECPU2 or ECRU w/NVMEM 1 board. <br /> Standard Models <br /> Vacuum Sensor Kits are available in a variety Veeder-Root P/N Description 1 <br /> of models 330020-467 4 Vacuum Sensor Kit'for steel tank <br /> 330020-468,-469,-470,-471 4 Vacuum Sensor Kit'for fiberglass tanks(4',6',8',10) <br /> 330020-486 4 Vacuum Sensor KV for no tank <br /> • For monitoring double-walled piping 330020-472 --- 3 Vacuum Sensor Kit'for steel tank <br /> and sum interstices 330020-473 474 475,-476 3 Vacuum Sensor KY for fiberglass tanks(4',6',8',10') 1 <br /> P 330020-485 3 Vacuum Sensor Kit'for no tank <br /> • For monitoring double-walled steel tank 330020-479 2 Vacuum Sensor Kt'for steel tank <br /> interstices(see back page) 330020-481,-482,-483,484 2 Vacuum Sensor Kit'for fiberglass tanks(4',6',8'.10' <br /> 330020-480 2 Vacuum Sensor Kit'for no tank <br /> • For double-walled fiberglass tanks1 <br /> 330020-495 1 Vacuum Sensor Kit'for no tank_ <br /> 857280-100 Vacuum Sensor for piping 8 sumps <br /> These kits differ in the number of vacuum 857280-200 - Vacuum sensor for steal tanks <br /> 857280-301 302,-303,-304 Vacuum Sensor for fiberglass tanks L4 6 8 1 0j_ <br /> — _ <br /> sensors and the COnfigUra[lOri of a550C1a[e 330020-448 Mounting Kit <br /> liquid sensors. An inline kit mounted liquid 332217-001. —Relief Valve assembly <br /> sensor is used for Vacuum Sensors <br /> 332250-001 Smart Sensor w/Embedded Pressure Sensor Module(7 Channe0" <br /> - - -- ---- - <br /> monitoring piping and sumps. An external Accessories Part Description Quantity/Length Pan Number <br /> 1/4'NPT Barbed Fittings __ _ 3 330020-487 <br /> liquid sensor(to be installed in the secondary 1/41 NPT Barbed Fittings _ 15 330020-488 , <br /> space at the bottom of the tank) is provided 114'NPT Barbed Fittings 25 330020 489 <br /> with one of the Vacuum Sensors in the steel Barbed Tee _ _ _ 1 576009657 _ <br /> Vacuum Hose 25' 25' 332310001 <br /> and fiberglass tank kits to monitor the tank. Vacuum Nose 50' __ 50' 332310-002 <br /> Vacuum Hose 100 100' 332310-003 1 <br /> 3-Way Ball Valve 1 576008-649 <br /> Schrader Valve Barbed Fitting 3 330020-496 <br /> Schrader Valve Barbed Fitting 15 330020-497 <br /> Kits include mounting bracket,set Vacuum hose,relief valva assembly Of required and the seasonal number of liquid sensors, <br /> 3-way ball vai barbed things and hose clamps so that each vacuum sensor can monitor a single tank,sump or piping interstices. 1 <br /> the Vacuum Sensing System requires are 7 chamel Smart Sensor Interlace with Embedded Presfure Module,8 channel Smart <br /> Sensor Modules(p/n 329358-004)can be used for Vacuum Sensors eight and above. <br /> For more information call: 1-888-561-7942 <br /> l�;� VEEDER-ROOT 1 <br />