INSTALL_2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
6009
>
2300 - Underground Storage Tank Program
>
PR0542116
>
INSTALL_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/18/2020 3:23:12 PM
Creation date
7/23/2020 1:45:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2018
RECORD_ID
PR0542116
PE
2351
FACILITY_ID
FA0024188
FACILITY_NAME
GRIN INVESTMENTS INC DBA: ARCO AM/PM
STREET_NUMBER
6009
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95207
APN
08126064
CURRENT_STATUS
01
SITE_LOCATION
6009 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
653
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'I I tlVI ?TZ 15 <br /> VEEDER-ROOT <br /> 1 <br /> IN STATION DIAGNOSTICS (ISD) <br /> 1 <br /> THE KEY TO CALIFORNIA COMPLIANCE OMM-1400, <br /> Veeder-Root's California Air Resources Product Components 1 <br /> Board(CARB)certified In-Stadon- .Assist Vapor Flow Meter-Designed to <br /> Diagnostics(ISD)system provides the withstand the harsh vapor recovery 1 <br /> most accurate vapor recovery detection - <br /> environment Found in systems with vapor <br /> available in the industry. - <br /> vacuum pumps.It provides ISD with the <br /> Veeder-Roots ISD system continuously volume of vapor recovered during vehicle TLS-350 <br /> monitors the vapor recovery equipment, refueling for continuous vapor collection <br /> maintains test records,provides test monitoring s - <br /> reports,and generates warnings or •Balance Flow Meter -Designed for use At 1 <br /> Vapor Flow Meter <br /> alarms following equipment failure. in pressure sensitive balance systems to 6 <br /> maintain accuracy and minimize false Q <br /> The Veeder-Root ISD system can be1 <br /> alarms.It provides ISD with the volume of <br /> added to any TLS-350 console.This vapor recovered during vehicle refueling for rR j <br /> provides you with a cost effective <br /> continuous vapor collection monitoring <br /> solution with the Veeder-Root quality EZA <br /> 1 <br /> and support that you expect. •Vapor Pressure Sensor -Provides ISD with <br /> tank ullage pressure for vapor containment <br /> The Most Installed ISD Solution leakage and overpressure monitoring <br /> •ISD Software Enhancement Module 1 <br /> Starting September 2010,ISD is (SEM)-Unlocks the ISD software in the ~ � 5 A <br /> 7 <br /> required on all gasoline dispensing TLS-350 to provide continuous vapor ice, <br /> facilities with an annual throughput over recovery monitoring 1 <br /> 600,000 gallons. Vapor Pressure Sensor <br /> •NVMEM 2 Board -Provides memory <br /> Whether assist or balance vapor expansion necessary for ISD report storage <br /> recovery,over 90%of California 1 <br /> customers have selected Veeder-Roots <br /> ISD system. New stations select the Benefits of the Veeder-Root ISD System <br /> Veeder-Roo[balance ISD solution due to Exceeds Compliance Requirements Cost Effective Solution 1 <br /> simpler nozzle alarm requirements. <br /> •CARB certified with all approved •ISD OEM can be added to any <br /> Veeder-Root's ISD is the only certified hanging hardware,providing California TLS-350 console,leveraging existing 1 <br /> solution that supports all vapor customers with the most options TLS-350 equipment <br /> processor configurations and all certified •Maximizes site uptime using Single •Minimizes initial equipment and <br /> vapor recovery nozzles. Dispenser Shutdown functionality installation costs 1 <br /> Flexible shutdown solutions allows •Flexible ISD solution certified with all •ISD Sensors can share wiring conduit <br /> customers to choose between STP Vapor Processor configurations with other Veeder-Root intrinsically <br /> shutdown,single dispenser shutdown or •CARB certified to meet all ISD performance safe(IS)sensors 1 <br /> use both configurations. requirements as defined by CP201 •Simple installation,compatible with all <br /> including at least a 95%probability of Dispensers <br /> failure detection while operating at no more 1 <br /> than a 1%probability of Use alarms •Single Dispenser or STP Shutdown <br /> •Continuous monitoring identifies failed •Wireless option available <br /> vapor recovery equipment during warranty •Veeder-Root warranty for one year from 1 <br /> /�1� periods without expensive manual testing date of installation for all new ISD <br /> l VEEDER-ROOT components 1 <br />