Laserfiche WebLink
SAN�JOAQUIN Department <br /> Environmental Health De <br /> —COUNTY— Linda Turkatte, REHS, Director <br /> Greatness grows here. Kasey Foley,REHS,Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellan, REHS <br /> Jeff Carruesco, REHS,RDI <br /> Rodney Estrada, REHS <br /> R E Ch @ Y� ,�E D Willy Ng,REHS <br /> December 21, 2017 ®!/_ @G \M/ Muniappa Naidu, REHS <br /> Josh Harlan JAN 19 2018 <br /> Barghausen Consulting Engineers, Inc. <br /> 18214 72nd Ave. ENVIRONMENTAL HEALTH <br /> Kent, WA 98032 DEPARTMENT <br /> Re: ARCO ampm SR0078036 <br /> 6009 N EI Dorado St. <br /> Stockton, CA 95207 <br /> The San Joaquin County Environmental Health Department (EHD) has completed the review of the <br /> application for a permit to install an underground storage tank (UST) system at the above noted <br /> address. Please provide the following additional information (three copies each) and address the <br /> following comments: <br /> 1. Page 7, of the permit application (under the section labeled overfill) should list the OPW <br /> flapper model number instead of the Veeder Root smart sensor model number. <br /> 2. Page 3, of the Application for Underground Storage Tank Installation Permit: <br /> a. Fire District Permit number is incorrect. <br /> 3. G.0.2.2, section 18, indicates that sumps will be tested hydrostatically (VPH sumps are not <br /> tested hydrostatically (SB989), clarification is needed). <br /> 4. G.0.5, indicates that valves are being installed on vacuum jumper tubing. Veeder root does <br /> not recommend installation of ball valves on vacuum jumper cables. Please provide <br /> clarification if these ball valves will be installed. <br /> 5. G.0.6.2, illustrates a direct bury spill bucket. Spill buckets must be installed in sumps. <br /> 6. G.0.6.4, under additional notes, #7 indicates ball floats are to be installed. Ball floats cannot <br /> be installed. <br /> 7. G.0.7.2, fill sump details doesn't match M.5.3.03 or M.5.3.18 sump details (sumps should <br /> look similar across install plans). <br /> 8. M.5.3.01, for number 34, and 35 lists both OPW and Containment Solutions spill bucket <br /> sump shield, please verify which one will be used. <br /> 9. M.5.3.03 and M.5.3.05: <br /> a. Buoyancy calculations need to be signed and stamped. <br /> b. Dry weight for split tank listed on calculations as 12873lbs. Total gallons used in <br /> buoyancy calculations listed as 22,000 gallons. Please provide a tank cut sheet that <br /> corresponds to the tank weight and total number of gallons. <br /> c. For#14, it states tank anchoring is optional. Tank anchoring is not optional. <br /> 10. M.5.3.16, fill sump detail on section A, and D look different from one another. <br /> If you have any further questions, please contact me at (209) 468-3453. <br /> Thank you, <br /> Aaron Hang, EHS <br /> Environmental Health Speci <br /> cc: Gupartarp Singh, Grin Investments, Inc., 62 N. Sierra Madre St., Mountain House, CA 95330 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />