FA0024188
FACILITY_NAME
GRIN INVESTMENTS INC DBA: ARCO AM/PM
STREET_NUMBER
6009
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95207
APN
08126064
CURRENT_STATUS
01
SITE_LOCATION
6009 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
653
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- Item #28 <br /> �- OPW 400 apd,,5Q� <br /> Series Multi-0212 pill <br /> Containment Manholes <br /> = `Manholrc�'o[c� inment <br /> for undr un storage tank(UST) <br /> FSA400 61JSK fill pipes and vapor recovery risers in a <br /> completely integrated single manhole <br /> See page s7 for - package. Multi-ports are installed over <br /> ordering specifications the top of tank sumps to preserve future <br /> on the FSA-400&61JSK 1 access to the tank top and to facilitate <br /> containment of tank bung fittings.OPW <br /> Model Descriptions Multi-PortThread-On Spill containers offers a vast array of standard multi-port <br /> ♦ OPW 411 Series—features a flush- are available in Composite or Cast Iron configurations and options, in addition <br /> mounted manhole lid and raised dual bases with 5 gallon buckets.Drain to an almost unlimited ability to provide <br /> dam and groove spill container rings, Valve Spill Bucket&Plug Spill Bucket custom solutions for virtually any spill <br /> with P2105 Buckets using OPW 1-2105 standard on Dual Ports,Drain Valve containment application. <br /> Style Slip-On 5-gallon containers. Base Spill Bucket standard on Single Port. <br /> is standard 1" offset from center and ♦ Required for EVR APPLICATIONS <br /> can be used for 12", 14", 16" or wider —the FSA-400 Threaded Riser Face ♦ Spill Container Cover Options— <br /> riser spacing.Optional 1 P-2105 Hand Seal Adaptor is installed on the fill standard spill container options include <br /> Pump available. pipe below the spill container to the patented OPW dam and groove <br /> ♦ OPW 500 Series(511 /521) EVR provide a true sealing for the drop raintight(RT)design and the <br /> tube flange on the 71 SO overfill watertight Sealable Cover(SC) <br /> Multi-Port features aflush- prevention valve.The 61 SO and/or "plumber's plug"design.The raintight <br /> mounted manhole lid and raised dual 71 SO series valve is installed in the cover features a finger-grip lifting <br /> dam and groove spill container ring, base of the OPW EVR spill container facility and an integral seal.The <br /> with tyl Buckets using OPW sealable cover features a cam-operated <br /> 1-21000 SStyle T Thread-On Spill with the patent pending 61JSKjack <br /> Containers.All Fill Ports in these spill screw device.This configuration allows mechanism that expands the seal <br /> containers feature an enhanced liquid in the spill container to be against the vertical wall of the <br /> 1 DK-2100-EVR vapor tight drain valve. drained directly into the drop tube, mounting ring.Both of these water- <br /> The Vapor Return Spill Container thereby isolating the drain valve from shedding covers are protected by <br /> features a permanent plug in the drain the tank ullage,eliminating a notorious raised mounting rings. <br /> port as per EVR requirements. EVR leak point in previous systems. ♦ Fastener Options—two types of <br /> fasteners are available to secure the <br /> Features • Fill/Vapor Ports—configurations are manhole lid and monitoring port to <br /> mounting rings.Standard are <br /> • Contractor-FriendlyInstallation available to accommodate a single fill 5/16"-18 hex head bolts.Optional <br /> riser,dual ports for both a fill and <br /> —studded mounting ring simply bolts vapor riser,and triple and quad ports are OPW Roto-Lock Fasteners. <br /> together inside the spill containment for multiple fill and vapor risers.Ports The OPW Roto-Lock system enables a <br /> bucket. No need to align bolt holes in can be supplied with or without secure,watertight connection without <br /> the manhole cover. containment buckets. the need to locate threaded bolt holes <br /> ♦ Raintight Service—nitrile gaskets ♦ port Configurations—standard port on the mounting ring. <br /> 40- Powder Coated Rings & Covers— <br /> on the manhole and spill bucket locations match the popular riser <br /> mounting rings help prevent spacings(16" or 24")and bung available upon request. <br /> contamination of the sump area configurations on underground storage ♦ Replacement Covers—see Part <br /> from surface water intrusion. tanks.Custom port locations are easily Number Configurations at <br /> ♦ Highway 20 Load Rating—the accommodated.For riser spacings less www.opwgiobal.com. <br /> rugged diamond plate steel manhole than 16",old style buckets must <br /> covers,as well as the ductile iron (RT) be used. Listings and Certifications <br /> or aluminum (SC)spill container covers ♦ CARB Certified—500 Series CARB <br /> meet H2O Load Rating requirements. EVR Approved Executive Order#VR-102 Look for this label for <br /> ♦ Spill Container and Manhole ♦ Manhole Cover Sizes—standardULC ItM authentic OPW EVR <br /> Positive I.D. System—special bolt-down manhole cover diameters Approved produce. <br /> recesses cast into spill container covers of 30" (76 cm),37" (94 cm),42" <br /> allow product I.D.tags to be attached (107 cm)and 48" (122 cm)allow CARB EVR Executive Order#VR-102 <br /> to the lids.Matching bucket tags can ample access to the sump area.Heavy- NYCFD Certified(6571 Series)#5053 <br /> be affixed to the inside of the spill duty reinforced lid options are also Florida EQ-145 <br /> container to prevent covers from available upon request. <br /> getting switched. <br /> 9393 Princeton-Glendale Road jHamilton,Ohio USA 45011 ii- Phone:(800)422-2525 -* Fax:(800)421-3297 www.opwgiobal.com 69 <br />
The URL can be used to link to this page
Your browser does not support the video tag.