Laserfiche WebLink
U� ONLINE CERTIFICATIONS DIRECTORY <br /> EQXX.MH11766 <br /> Control, Monitoring and Auxiliary Equipment <br /> Page Bottom <br /> Control, Monitoring and Auxiliary Equipment <br /> See General Information for Control. Monitoring and Auxiliary Eouioment <br /> VEEDER-ROOT CO MH11766 <br /> 125 POWDER FOREST DR <br /> PO BOX 2003 <br /> SIMSBURY,CT 06070 USA <br /> Wireless line leak detectors, Form Nos. 849470-001, -002,-003,-005, PA0263000100, -002, -003. <br /> Electronic meter register systems,designated EMR3 consisting of one or two electronic meter registers Form No. 8456 followed by 9,followed <br /> by 2 thru 9,followed by one or more numbers and interconnect box Form No. 8458 followed by 93,followed by 0, 1 or 2,followed by 0 or 1, <br /> followed by 1 or 2. For use with peripheral equipment as specified by the installation instructions. <br /> Associated Apparatus,Nonhazardous location,Inventory Measurement System,designated TLS-IB,consisting of Form No. 846690-180, - <br /> 280, -380 or-480 control unit for use with up to eight probes, Form Nos. 8462, 8463,8563 or 8570 and/or Mag Flex Probe model 8895 and/or <br /> Mag Plusl,intrinsically safe for use in Class I, Div. 1, Group D when installed as per Control Drawing Number 331940-014. May be used with <br /> peripheral equipment as specified by the installation instructions. May be provided with an overfill alarm Form No. 790091-001 with or without an <br /> acknowledgement switch Form No. 790095-001. <br /> Associated Apparatus, Nonhazardous location,Inventory Measurement System,designated TLS-50, consisting of Form No. 846990-060, - <br /> 160, -230 or-260 control unit for use with up to six probes, Form Nos. 8462, 8463,8563 or 8570 or Mag Plusl, intrinsically safe for use in Class I, <br /> Div. 1,Group D when installed as per Control Drawing Number 331940-014. May be used with peripheral equipment as specified in the installation <br /> instructions. May be provided with an overfill alarm Form No. 790091-001 with or without an acknowledgement switch Form No. 790095-001. <br /> Associated Apparatus, Nonhazardous location,Inventory Measurement System,designated TLS-HLD, consisting of Form No. 846990-360 <br /> control unit for use with up to six probes, Form Nos. 8462, 8463, 8563 or 8570 or Mag Plusl, intrinsically safe for use in Class I,Div. 1,Group D <br /> when installed as per Control Drawing Number 331940-014. May be used with peripheral equipment as specified in the installation instructions. <br /> May be provided with an overfill alarm Form No. 790091-001 with or without an acknowledgement switch Form No. 790095-001. <br /> Associated Apparatus,Nonhazardous locations,Inventory Measurement System, designated TLS-2, consisting of Form No. 856090-X6Y, <br /> where X and Y are any character or 856092-060 control unit for use with up to six probes, Form Nos. 8462, 8463, 8563 or 8570 or Mag Plusl, <br /> intrinsically safe for use in Class I, Div. 1,Group D,when installed as per control drawing number 331940-014 . May be used with peripheral <br /> equipment as specified in the installation instructions. May be provided with overfill alarm Form No. 790091-001 with or without an <br /> acknowledgment switch Form No. 790095-001. <br /> Associated Apparatus, Nonhazardous location,Inventory Measurement System,designated TLS-300 consisting of control unit, Form No. <br /> 84859X-XXX where X can be any character may be connected to thirty-two intrinsically safe sensors or probes. May also be provided with overfill <br /> alarm Form No. 790091-001 with or without acknowledgement switch Form No. 790095-001.The probes and sensors have been evaluated for use <br /> in Class I, Div. 1, Group D hazardous locations when connected in accordance with control drawing number 331940-013.The following probes and <br /> sensors are suitable for this system: <br /> Magnetostrictive probes, Basic Form Nos. 8462, 8463,8563,8570; <br /> Liquid or Vapor Sensors, Basic Form Nos. 7943 with or without 80 or 90 maybe be followed by three characters; <br /> 2 to 1 Sensor Input Boxes, Form No. 857390-102; <br /> Oil/Water Separator Sensor, Basic Form No. 7946; <br /> UL Listed Submersible Pump, Models PC or PAGC; or Mag Plusl. <br /> Liquid level gauge/leak detection system,designated TLS-450/8600.Associated Apparatus,non-hazardous location, liquid level <br /> gauge/leak detector control unit, Form No. 8600,followed by 90,followed by 1 followed by 00, provides intrinsically circuits for use in Class I, Div. <br /> 1, Group D, may be used with up to 16 intrinsically safe probes/sensors per USM Module when installed in accordance with Control Drawing <br /> 331940-008.Suitable Intrinsically Safe Devices for use in Class I, Div. 1, Group D are 2 to 1 Sensor Input Box, Form No. 857390-102 only <br /> for use with Sump, Position Sensitive and Hydrostatic Sensors, Form Nos. 794380, followed by-208, -209, -301,-304, -323, -333; or <br /> Magnetostrictive probes, Form No. 84639, followed by 0 to 9,followed by 0 to 9,followed by 00 to 99 or Form No. 85639,followed by 0 or 1, <br /> followed by 0 to 9,followed by 00 to 99,or Form No. 857080,or Form No. 846291,followed by-100 through-199 or ISD Flow Meter Form No. <br />