My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0006653 CASE 1
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
707
>
2900 - Site Mitigation Program
>
PR0500097
>
ARCHIVED REPORTS_XR0006653 CASE 1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/23/2020 3:28:50 PM
Creation date
7/23/2020 3:20:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0006653 CASE 1
RECORD_ID
PR0500097
PE
2950
FACILITY_ID
FA0001329
FACILITY_NAME
PONTES QUICKI KLEEN CAR WASH
STREET_NUMBER
707
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22323013
CURRENT_STATUS
01
SITE_LOCATION
707 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> ' 30 October 2002 <br /> • AGE-NC Project No 98-0492 <br /> Page 3 of 4 <br /> 3 2 ANALYTICAL RESULTS OF GROUND WATER SAMPLES <br /> rMTBE was detected In the water sample collected from well MW2 at a concentration of 0 60 gg/l <br /> No additional analytes were detected at or above laboratory reporting limits in the ground water <br /> ' samples <br /> The analytical results of ground water samples are summarized on Table 3 The laboratory reports <br /> ' (MAI Lab I D No 0208115-001 through 0208115-003), QA/QC report and chain-of-custody form <br /> are included in Appendix B <br /> ' 4.0 SUMMARY AND CONCLUSIONS <br /> ' Based on the data collected from the site, AGE concludes <br /> • The depth to ground water at the site on 07 August 2002was between 23 10 to 24 37 feet <br /> ' below the well casing tops The prevailing ground water flow direction at the site was <br /> generally toward the northwest with a hydraulic gradient of 0 002 feet/feet, consistent with <br /> the previously determined flow directions Ground water elevations at the site decreased an <br /> '! average 2 84 feet between the May 2002 and August 2002 sampling events <br /> • MTBE was detected in the water sample collected from well MW2 at a concentration of <br /> ' 0 60 gg/1 The concentration of MTBE detected is below the State of California Primary <br /> Maximum Contaminant Level (MCL) of 5 0 gg/l for MTBE in drinking water <br /> • No other analytes were detected at or above laboratory reporting limits in the ground water <br /> ' samples analyzed <br /> ' 5.0 RECOMMENDATIONS <br /> ' Based on the findings of the environmental activities recounted in this report,AGE recommends the <br /> site be considered for closure due to low and non-detectable concentrations of contaminants in the <br /> samples collected from wells MW 1, MW2 and MW3 over the past three quarters <br /> 1 <br /> 1 <br /> 1 <br /> ' Advanced GcoEnvironmental,Inc <br /> r <br />
The URL can be used to link to this page
Your browser does not support the video tag.