RECORD_ID
PR0506303
PE
2965
FACILITY_ID
FA0001086
FACILITY_NAME
MANTECA PUBLIC WORKS
STREET_NUMBER
2450
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
24130050
CURRENT_STATUS
01
SITE_LOCATION
2450 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
120
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING AND REPORTING PROGRAM NO. R5-2004-0028 11 <br /> NPDES NO. CA0081558 <br /> CITY OF MANTECA, CITY OF LATHROP AND DUTRA FARMS <br /> WASTEWATER QUALITY CONTROL FACILITY <br /> SAN JOAQUIN COUNTY <br /> 1 Groundwater elevation shall be used to calculate the direction and gradient of groundwater flow. <br /> Elevations shall be measured to the nearest one-hundredth of a foot from mean sea level. The <br /> groundwater elevation shall be measured prior to purging the wells. <br /> 2 A hand-held field meter may be used,provided the meter utilizes a USEPA-approved <br /> algorithm/method and is calibrated and maintained in accordance with the manufacturer's <br /> instructions. <br /> WATER SUPPLY MONITORING <br /> A sampling station shall be established where a representative sample of the municipal water supply can <br /> be obtained. The following shall constitute the water supply monitoring program. <br /> Sampling <br /> Constituents Units Freauency <br /> Standard Minerals' mg/l Yearly <br /> Electrical Conductivity, umhos/cm Yearly <br /> @ 25°C <br /> Total Dissolved Solids mg/1 Yearly <br /> 1 Standard minerals shall include all major cations and anions, including calcium, <br /> magnesium, hardness, sodium,potassium, alkalinity, sulfate, chloride, boron, and nitrate, <br /> and verification that the analysis is complete (i.e., cation/anion balance). <br /> z If the water supply is from more than one source,the EC shall be reported as a weighted <br /> average and include copies of supporting calculations. <br /> REPORTING <br /> Monitoring results shall be submitted to the Regional Board by the first day of the second month <br /> following sample collection. Quarterly and annual monitoring results shall be submitted by the first day <br /> of the second month following each calendar quarter, semi-annual period, and year, respectively. <br /> In reporting the monitoring data, the Discharger shall arrange the data in tabular form so that the date, <br /> the constituents, and the concentrations are readily discernible. The data shall be summarized in such a <br /> manner to illustrate clearly whether the discharge complies with waste discharge requirements. The <br /> highest daily maximum for the month,monthly and weekly averages, and medians, and removal <br /> efficiencies(%) for BOD and Suspended Solids, should be determined and recorded. <br />