Laserfiche WebLink
Procedure Na. Revision Number <br /> ERD SOP-2.10 3 Page 4 of 4 <br /> ' 6.3 Post Operation <br /> 6.3.1 Perform post operation per SOP 4.1. <br /> ' 6.3.2 Before leaving the sampling site, cross check sample containers with those <br /> recorded in the logbook. <br /> 6.3.3 To maintain and document sample custody,follow the procedure for completing a <br /> Chain-of-Custody(CoQ form in SOP 4.2,"Sample Control and Documentation." <br /> 6.3.4 After all samples are collected and preserved as necessary, any non-dedicated <br /> sampling equipment should be decontaminated prior to sampling another site in <br /> order to prevent cross-contamination of equipment between locations (see <br /> SOP 4.5,"General Equipment Decontamination"). <br /> 6.3.5 Deliver all field logbook notes (upon request), Ground Water Sampling Data <br /> ' Sheets, and(CoQ forms to the SC daily. <br /> 6.3.6 The SC will retain copies of the Ground Water Sampling Data Sheets and provide <br /> the originals to the Data Management Team (DMT) for final archive. The SC <br /> t will provide copies of the forms to the appropriate Operations and Regulatory <br /> Affairs Division Analyst, as necessary. <br /> 6.3.7 Submit the coliform samples to the analytical laboratory as soon as possible due <br /> to the short holding time for coliform analyses (6 hours). <br /> ' 7.0 QA RECORDS <br /> 7.1 Ground Water Sampling Data Sheets <br /> 7.2 Document Control Logbooks <br /> 7.3 Chain-of-Custody Forms <br /> ' 8.0 ATTACHMENTS <br /> ' Not applicable. <br /> 1 <br /> 1 <br />