Laserfiche WebLink
should be stated. All analyses shall be performed by a <br /> Describe the treatment processes including loading rates laboratory approved by the State Department of Health <br /> and contact times; Services. <br /> All filtration design criteria should be provided (filtration 2.9 Contingency Plan <br /> and backwash rates, filter depth and media specifications, <br /> etc.) . The expected turbidities of the filter influent (prior Section 60323 (c) of the Water Recycling Criteria requires <br /> to the addition of chemicals) and the filter effluent should that the engineering report contain a contingency plan <br /> be stated; designed to prevent inadequately treated wastewater from being <br /> delivered to the user. The contingency plan should include: <br /> State the chemicals that will be used, the method of mixing, <br /> the degree of mixing, the point of application, and the * A list of conditions which would require an immediate <br /> dosages. Also describe the chemical storage and handling diversion to take place; <br /> facilities, and <br /> * A description of the diversion procedures; <br /> Describe the operation and maintenance manuals available. <br /> * A description of the diversion area including capacity, <br /> 2.6 Plant Reliability Features holding time and return capabilities; <br /> The plant reliability features proposed to comply with * A description of plans for activation of supplemental <br /> Sections 60333 - 60355 of the Water Recycling Criteria should supplies (if applicable); <br /> be described in detail. The discussion of each reliability <br /> feature should state under what conditions it will be * A plan for the disposal or treatment of any inadequately <br /> actuated. When alarms are used to indicate system failure, treated effluent; <br /> the report should state where the alarm will be received, how <br /> the location is staffed, and who will be notified. The report * A description of fail safe features in the event of a <br /> should also state the hours that the plant will be staffed. power failure, and <br /> 2.7 Supplemental Water Supply A plan (including methods) for notifying the recycled <br /> water user(s), the regional board, the state and local <br /> The report should describe all supplemental water supplies. health departments, and other agencies as appropriate, of <br /> The description should include: any treatment failures that could result in the delivery <br /> of inadequately treated recycled water to the use area. <br /> * Purpose <br /> 3.0 TRANSMISSION AND DISTRIBUTION SYSTEMS <br /> * Source <br /> Maps and/or plans showing the location of the transmission <br /> * Quality facilities and the distribution system layout should be provided. <br /> The plans should include the ownership and location of all potable <br /> * Quantity available water lines, recycled water lines and sewer lines within the <br /> recycled water service area and use area(s) . <br /> * Cross-connection control and backflow prevention measures <br /> 4.0 USE AREAS <br /> 2.8 Monitoring and Reporting <br /> The description of each use area should include: <br /> The report should describe the planned monitoring and <br /> reporting program, including all monitoring required by the * The type of land uses; <br /> Water Recycling Criteria, and include the frequency and <br /> location of sampling. Where continuous analysis and recording * The specific type of reuse proposed; <br /> equipment is used, the method and frequency of calibration <br /> 4 5 <br />