Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HOOD
>
5655
>
2300 - Underground Storage Tank Program
>
PR0540345
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/27/2020 1:37:08 PM
Creation date
7/27/2020 11:44:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0540345
PE
2351
FACILITY_ID
FA0023065
FACILITY_NAME
FedEx Ground - Tracy
STREET_NUMBER
5655
STREET_NAME
HOOD
STREET_TYPE
Way
City
Tracy
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
5655 Hood Way
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FED EX TRACY FINDINGS AU6 2 3 2018 <br /> ENV/RO <br /> -BIO SPILL BUCKET OPW SPILL BUCKET IN CONTAINMENT FI J 7-A <br /> -BIO <br /> TORN NEEDS TO BE ORDERED AND REPLACED NEED TO QUOTE 'w <br /> SPILL BUCKET AND LABOR OR HOURLY RATE INSTALL. <br /> -DIESEL#2 BRINE LEAK APPEARED TO BE LEAKING FROM BALL VALVE AT <br /> BOTTOM OF CONTAINMENT, INSTALLED 1/4"PLUG IN END OF BALL VALVE <br /> WITH PIPE SEALANT APPEARD TO HAVE STOPPED LEAK, ALSO FIXED <br /> SMALL DIESEL LEAK AT QUICK CONNECT FITTING ON END OF PRODUCT <br /> FLEX LINE. <br /> -BIO BLEND SUMP BRINE LEAK FOUND LEAK AT BOTTOM OF BRINE <br /> RESIVOIR , REMOVED HOSE BARB FROM RESIVOIR APPLIED PIPE SEALANT <br /> AND RETIGHTEND <br /> -VENT LINE SEC. COMMUNICATION, ALL VENT LINES HAVE SECONDARIES <br /> ARE MANIFOLDED TOGETHER IN VENT BOX AND ARE ON ONE VAC <br /> SENSOR S3 WITH BALL VALVE TO CONFIRM COMMUNICATION IN BIO STP <br /> SUMP AND VAC SENSOR LOCATED IN DIESEL 1 STP SUMP , CONFIRMED <br /> COMMUNICATION OF VENT VACUUM IN DIESEL+STP 2 SUMP , THEN <br /> RELEASED ALL CONTAINMENT VACUUM AT BIO STP SUMP THROUGH <br /> BALL VALVE IS A LARGE CONTAINMENT AREA TOOK ABOUT 5 MIN TO <br /> RELEASE ALL VACUUM S3 SENSOR DID GO INTO ALARM. <br /> -FOUND VACUUM SENSOR SI TURNED OFF (THIS VAC SENSOR MONITORS 3 <br /> CONTAINMENTS) THIS SENSOR MONITORS #1 DIESEL LINE TO DISP. 5 <br /> (THAT PRODUCT LINE IS DEDICATED TO DISP. 5 ONLY) , #2 BIO DIESEL <br /> PROD LINE , #3 DIESEL TANKS.SYPHON LINE, AS SOON AS I TURNED <br /> SENSOR ON IT WENT INTENSOR FAULT ALARM , THERE WAS A SPARE <br /> VACUUM SENSOR INSTA L NEXT TO THE DEFECTIVE SENSOR SO I <br /> SWAPPED SENSORS , S1 NOW WORKING PROPERLY , PROCEEDED TO LET <br /> VEEDER ROOT PULL VACUUM ON THE CONTAINMENTS, CONFIRMED <br /> COMMUNICATION WITH SYPHON LINE CONTAINMENT AND BIO LINE <br /> CONTAINMENT, AT FIRST COULD NOT CONFIRM COMMUNICATION OF <br /> VACUUM IN DIESEL LINE IN UDC #5 THE TEST PORT WAS CLOGGED WITH <br /> GLUE AT TIME INSTALLATION, ATTEMPTED TO CLEAR GLUE FROM TEST <br /> PORT UNSUCCESSFULLY, THERE WAS A SECOND TEST PORT THAT WAS <br /> PLGGED ON SIDE OF TEST BOOT INSTALLED HOSE BARB AND BALL VALVE <br /> AT THAT PORT COMMUNICATION WAS THEN VERIFIED. <br /> -DEF LINES NON VAC SENSOR COMMUNICATION THIS WAS A NON ISSUE <br /> THE DEF LINES ARE DOUBLE WALL BUT NEVER HAD VACUUM SENSOR <br /> INSTALLED ON THEN THEY ARE A OPEN LOOP CONTAINMENT ANY LEAKS <br /> WOULD TRAVEL BACK TO STP SUMP SHUTTING DOWN PUMPING SYSTEM , <br />