Laserfiche WebLink
S0 JOA U 1 Environmental Health Department <br /> u ;� i Y I <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TRACY MARKET INC 15 E GRANT LINE RD, TRACY November 01, 2019 <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 113 CCR 2638(c), 2638(d) Failure to submit"Monitoring System Certification Form"within 30 days of completion of the <br /> test. <br /> Annual monitoring system certification and leak detector testing testing was performed on 11/29/2019 and a test <br /> report was submitted on 12/31/2019, 32 days later. A copy of the test report must be submitted within 30 days of <br /> the tests. Take all necessary precautions to ensure testing and submittal of test reports are performed in a timely <br /> manner. <br /> This is a minor violation. <br /> 121 CCR 2712(f)Failure to implement corrections and submit written response within 30 days of receiving the report. <br /> An inspection was last done on 11/29/2019 and an inspection report was issued identifying information to be <br /> submitted to bring this site into compliance. This information was required to be submitted by 12/29/2019. This <br /> information has not been received resulting in a non-compliant status for this facility. An operator that receives an <br /> inspection report shall have 30 days to implement the corrections specified in the inspection report and comply with <br /> permit conditions. The corrective action shall include all of the recommendations made in the report. The operator <br /> shall submit a written response that includes a statement documenting corrective actions taken or proposing <br /> corrective actions which will be taken. Ensure that a written response documenting corrective actions taken or <br /> proposed is submitted and all corrections implemented within 30 days of receiving an inspection report. <br /> This is a Class II violation. <br /> 123 CCR 2637.1(d), 2637.1(e)Failure to submit the"Spill Container Testing Report Form"within 30 days after the test. <br /> Spill container testing was performed on 11/29/2019 and a test report was submitted on 12/31/2019, 32 days later. <br /> A copy of the test report must be submitted within 30 days of the tests. Take all necessary precautions to ensure <br /> testing and submittal of test reports are performed in a timely manner. <br /> This is a minor violation. <br /> 124 CCR 2637.2(d&e), 2665(a&b)"Overfill Prevention Equipment Inspection Report Form" not submitted within 30 days <br /> of inspection. <br /> Overfill prevention testing was performed on 11/29/2019 and a test report was submitted on 12/31/2019, 32 days <br /> later. A copy of the test report must be submitted within 30 days of the tests. Take all necessary precautions to <br /> ensure testing and submittal of test reports are performed in a timely manner. <br /> This is a minor violation. <br /> FA0002915 PR0231404 SCO01 11/01/2019 <br /> EHD 23-01 Rev.9/20/2019 Page 4 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />