My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
1617
>
2300 - Underground Storage Tank Program
>
PR0231923
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2021 3:43:10 PM
Creation date
7/27/2020 2:14:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
139
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM(Page i of e) <br /> Type of Action ❑Installation Test 0 Repair Test 0 Six Month Test p 36 Month Test <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10181235 5/14/2019 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> Arco 5450 <br /> Business Site Address City ZIP Code <br /> 1617 W. Fremont Stockton 195203 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test(Print as shown on the ICC Certification) Phone# <br /> David Rouse (925) 551-7555 <br /> Contractor 1 Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 220793 8292530 6/25/2020 <br /> III. SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> TANK ID:(By tank number,stored product,etc) A T-1 Unleaded B T-2 Unleaded C T-3 Premium D <br /> Tank Containment <br /> Tightness Test Result p Pass ❑Fail ❑NA p Pass ❑Fail ❑NA p Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Product Piping Containment <br /> Tightness Test Result p Pass ❑Fail ❑NA [l Pass ❑Fa-1 ❑NA El Pass ❑Fail ❑NA ❑Pass ❑Fail [INA <br /> Communication Test Result El Pass ❑Fail ❑NA IS Pass ❑Fail ❑NA E7 Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Remote Fill Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail p NA ❑Pass ❑Fail Cp NA ❑Pass ❑Fail M NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑Fail p NA ❑Pass ❑Fail M NA ❑Pass ❑Fail p NA ❑Pass ❑Fail ❑NA <br /> Vent Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail p NA ❑Pass ❑Fail E7 NA ❑Pass ❑Fail El NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑Fail p NA ❑Pass ❑Fail 17 NA ❑Pass ❑Fail p NA ❑Pass ❑Fail ❑NA <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail ©NA ❑Pass ❑Fail p NA ❑Pass ❑Fail p NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑Fail [DNA ❑Pass ❑Fail ©NA ❑Pass ❑Fail M NA ❑Pass ❑Fail ❑NA <br /> Turbine t Product Piping Sump <br /> Tightness Test Result p Pass ❑Fail ❑NA El Pass ❑Fail ❑NA p Pass ❑Fal ❑NA ❑Pass ❑Fail ❑NA <br /> Fill Riser Sump <br /> Tightness Test Result p Pass ❑Fail ❑NA EI Pass ❑Fail ❑NA El Pass ❑Fail ❑NA ❑Pass ❑Fa,l ❑NA <br /> VENT l TRANSITION SUMP ID: a b C d <br /> Tightness Test Result ❑Pass ❑Fail O NA ❑Pass ❑Fail p NA ❑Pass ❑Fail I]NA ❑Pass ❑Fail ❑NA <br /> UDC ID: 1 112 2 314 3 516 4 718 <br /> Tightness Test Result El Pass ❑Fail ❑NA p Pass ❑Fail ❑NA E7 Pass ❑Fail ❑NA ©Pass ❑Fail ❑NA <br /> UDC ID: 5 6 7 8 <br /> Tightness Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA E7 Pass ❑Fall ❑NA <br /> UDC In: 9 10 11 12 <br /> Tightness Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> All items marked"Fail"or"NA"must be explained in their respective"COMMENTS"section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the secondary containment was tested in ordance with California Code of Regulations,Title 23,Division <br /> 3,Chapter 16,Section 2637 and all the Inf atlon c ine re, is accurate. <br /> UST Service Technician Signature <br /> CERS=Ca6foria Environmental Reporting System,ID=Identificabor.UST=Underground Storage Tank ICC=International Code Council,NA=Not Applicable,UDC=Under- <br />