Laserfiche WebLink
OPW Installation and Maintenance Instructions <br /> 53VM / 30MV AND 233 SERIES BALL FLOAT/ EXTRACTOR ASSEMBLIES <br /> IMPORTANT: Please read these warnings and use the assembly instructions completely and carefully before <br /> starting. Failure to do so may cause product failure, or result in environmental contamination due to liquid leakage <br /> into the soil, creating hazardous spill conditions. <br /> IMPORTANT: Check to make sure the unit is intact and undamaged and all parts have been supplied. Never <br /> substitute parts for those supplied. Doing so may cause product failure and void warranty. <br /> WARNING-DANGER: Using electrically operated equipment near gasoline or gasoline vapors may result in a fire or explosion,causing <br /> personal injury and property damage. Be sure that the working area is free from such hazards,and always use proper precautions. <br /> NOTE:At all times when product is in the storage tank keep the riser pipe capped,so the vapors cannot escape into the environment. <br /> Notice:OPW products must be used in compliance with applicable federal,state,and local laws and regulations. Product selection should be <br /> based on physical specifications and limitations and compatibility with the environment and material to be handled. All illustrations and <br /> specifications in this literature are based on the latest production information available at the time of publication. Prices, materials,and <br /> specification are subject to change at any time,and models may be discontinued at any time,in either case,without notice or obligation. <br /> WARNING: OPW Overfill Warning Systems should only be used on submerged pumping systems, <br /> and not with suction pump systems. OPW Overfill Warning Systems should only be used on gravity drop <br /> systems. DO NOT use where Pump Off Unloading is used <br /> IMPORTANT:Installing the incorrect length OPW 53V or 30MV Ball Float Vent Valve for your specific application may <br /> result in delivery flow restriction at tank levels exceeding requirements established by the U.S. EPA. Always consult the <br /> appropriate tank charts and determine the specifics of your tank installation to determine the appropriate length OPW 53V or <br /> 30MV to be installed. The illustration and instructions on the back of this sheet are intended to serve as a guide in this <br /> determination. <br /> Field Installation Instructions <br /> 1. Apply a non-hardening, gasoline resistant pipe compound on the ball float nipple threads. Install the <br /> extractor cage-assembly onto the ball float nipple. Torques for, 3"NPT thread, 125 ft-lbs min. to 200 ft-lbs <br /> max, 2"NPT thread, 100 ft-lbs min. to 150 ft-lbs max. DO NOT USE TEFLON TAPE <br /> 2. Thread the 233 Series OPW Extractor Fitting into the tank bung fitting. Torque for, 4"NPT thread, 125"ft- <br /> lbs min. to 250 ft-lbs max. Thread the Ball Float and cage assembly into the 233 extractor fitting using <br /> the OPW 89 Extractor Wrench. Torque for, 3 3/4-8 thread, 75 ft-lbs min. to 150 ft-lbs max. <br /> 3. Make sure Ball Float moves freely, full stroke, without binding. <br /> 4. Preventative Maintenance- Every three years, remove and inspect the valve for damage, <br /> contamination, corrosion, freedom of movement of the ball float, and check the bleeder orifice for proper <br /> airflow. Replace if damaged or corroded. <br /> Important: Leave these instructions with Station Operator. <br /> Standard Product Warranty <br /> OPW warrants that products sold by it are free from defects in materials and workmanship for a period of one year from the date of <br /> manufacture by OPW(ECO products two years from date of manufacture.)Proof of purchase may be required. As the exclusive remedy <br /> under this limited warranty,OPW,will at its sole discretion,repair,replace,or issue credit for future orders for any product that may prove <br /> defective within the one year date of manufacture period(repairs, replacements,or credits may be subject to prorated warranty for remainder <br /> of the original warranty period,complete proper warranty claim documentation required.) This warranty shall not apply to any product that has <br /> been altered in any way,which has been repaired by any party other than a service representative authorized by OPW,or when failure is due <br /> to misuse,or improper installation or maintenance. OPW shall have no liability whatsoever for special,incidental or consequential damages to <br /> any party,and shall have no liability for the cost of labor,freight,excavation,clean up,downtime,removal,reinstallation,loss of profit,or any <br /> other cost or charges. <br /> For any product certified to California 2001 standards,OPW warrants that product sold by it are free from defects in material and <br /> workmanship for a period of one year from date of manufacture or one year from date of registration of installation not to exceed 15 months <br /> from date of manufacture by OPW. <br /> THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES,EXPRESS OR IMPLIED,AND SPECIFICALLY THE WARRANTIES OF <br /> MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO WARRANTIES,WHICH EXTEND BEYOND THE <br /> DESCRIPTION ON THE FACE HEREOF. <br /> OVER <br />