ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231923
PE
2361
FACILITY_ID
FA0003606
FACILITY_NAME
ARCO 05450
STREET_NUMBER
1617
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
13511015
CURRENT_STATUS
01
SITE_LOCATION
1617 W FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
139
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PREVENTATIVE MAINTENANCE <br /> Annually, inspect the flapper in the 71 SO to see that it is open by looking down the drop tube opening. Test the <br /> 71 SO drop tube seals with CARB procedure TP-201.1 D. If the drop tube seal passes testing, no further <br /> maintenance is required. If the drop tube fails testing, replace the drop tube seal with OPW P/N: H11931 M for 4" <br /> Tubes. Re-test the 71 SO drop tube with CARB procedure TP-201.1D. The lower tube o-ring seal OPW P/N: <br /> H14840M can also be replaced. If this does not correct the leak the 71 SO needs to be replaced. <br /> CAUTION: Do not insert any foreign object into drop tube if flapper is in the closed position. For example <br /> a tank level measuring stick. This will damage the valve and void the Warranty. ALWAYS check flapper <br /> location before "sticking" the tank. If flapper is in the closed position the tank is either over filled and you <br /> need to wait until the liquid level goes down or the 71 SO is damaged and needs to be replaced. <br /> 71 SO Performance Specifications: <br /> This Overfill Prevention Valve has been manufactured and tested to, and met, the following California <br /> specifications. Performance Requirement: Leak rate to be less than or equal to 0.17 CFH @ 2.0"W.C. <br /> Torque Specification: <br /> Taptite Screws, #10-24 thread cutting, 20 in-lbs minimum to 35 in-lbs maximum. <br /> Important: Leave these installation instructions and maintenance procedures with the station <br /> operator. <br /> Notice: OPW products must be used in compliance with applicable federal, state, and local laws and regulations. Product <br /> selection should be based on physical specifications and limitations and compatibility with the environment and material to be <br /> handled. All illustrations and specifications in this literature are based on the latest production information available at the time <br /> of publication. Prices, materials, and specification are subject to change at any time, and models may be discontinued at any <br /> time, in either case,without notice or obligation. <br /> Standard Product Warranty <br /> OPW warrants that products sold by it are free from defects in materials and workmanship for a period of one year from the <br /> date of manufacture by OPW(ECO products two years from date of manufacture.) Proof of purchase may be required. As the <br /> exclusive remedy under this limited warranty, OPW, will at its sole discretion, repair, replace, or issue credit for future orders <br /> for any product that may prove defective within the one year date of manufacture period (repairs, replacements, or credits may <br /> be subject to prorated warranty for remainder of the original warranty period, complete proper warranty claim documentation <br /> required.) This warranty shall not apply to any product that has been altered in any way,which has been repaired by any party <br /> other than a service representative authorized by OPW, or when failure is due to misuse, or improper installation or <br /> maintenance. OPW shall have no liability whatsoever for special, incidental or consequential damages to any party, and shall <br /> have no liability for the cost of labor,freight, excavation, clean up, downtime, removal, reinstallation, loss of profit, or any other <br /> cost or charges. <br /> For any product certified to California 2001 standards, OPW warrants that product sold by it are free from defects in <br /> material and workmanship for a period of one year from date of manufacture or one year from date of registration of <br /> installation not to exceed 15 months from date of manufacture by OPW. <br /> THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,AND SPECIFICALLY THE <br /> WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO WARRANTIES, <br /> WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. <br /> F31 o � <br /> A DOVER COMPANY <br /> P.O. Box 405003 * Cincinnati, Ohio 45240-5002 <br /> 1-800-422-2525 Domestically <br /> 513-870-3315 Internationally <br /> www.opw-fc.com <br /> Copyright, 2007 - OPW Fueling Components Inc., Cincinnati, OH <br /> Printed in U.S.A. p/n H15524PA— Rev. F 9/07 <br /> OPW 71 SO Overfill Prevention Valve Page 14 <br />