Laserfiche WebLink
CORLA-8 <br /> CORE LABORATORIES <br /> 0 U A L I T Y A S S U R A N C E F 0 0 T E R <br /> METHOD REFERENCES <br /> (1) EPA SW-846, Test Methods for Evaluating Solid waste, Third Edition, September 1986, and Updates 1, I1, IIA, IIB, and III <br /> (2) Standard Methods for the Examination of Water and Wastewater, 18th Edition, 1995 <br /> (3) EPA 600/4-79-020, Methods of Chemical Analysts for Waters and Wastes, March 1983 <br /> (4) Federal Register, Friday, October 26, 1984 (40 CFR Part 136) and amendments <br /> (5) American Society for Testing and Materials, Volumes 5.01, 5 02, 5 03, 1992 <br /> (6) EPA 600/4-89-001, Short-term Methods for Estimating the Chronic Toxicity of Effluents and Receiving Waters to Fresh <br /> Water Organisms <br /> (7) EPA 600/4-90-027, Methods for Measuring the Acute Toxicity of Effluent and Receiving Waters to Fresh Water and Marine <br /> Organisms, Fourth Edition <br /> COMMENTS <br /> All methods of chemical analysis have a statistical uncertainty associated with the results Unless otherwise indicated, <br /> the data in this report are within the Limits of uncertainty as specified in the referenced method Quality control <br /> acceptance criteria are based either on Limits specified in the referenced method or on actual Laboratory performance. <br /> The date and time of analysis indicated on the report may not reflect the actual time of analysis for QC samples Data <br /> reported in the QC report may be Lower than sample data due to dilution of samples into the calibration range of the anatysis <br /> Sample concentrations for solid samples are calculated on an as received (wet) basis unless otherwise indicated Unless <br /> otherwise indicated, volatites by gas chromatography (GC) are reported from a single Colum Volatiles analyses by GC on low <br /> level soils are conducted at room temperature TCLP extractions are performed at sample amounts, approved by the state of <br /> California <br /> FLAGS, FOOTNOTES, AND ABBREVIATIONS (as needed) <br /> = Not analyzed N I. = Not Ignitable <br /> N/A = Not applicable S I. = Sustains Ignition <br /> ug/L = Micrograms per liter I(HS) = Ignites, but does not Sustain ignition <br /> mg/L = Milligrams per liter RPD = Relative Percent Difference <br /> ND = Not detected at a value greater than the reporting limit <br /> NC = Not calculable due to values lower than the detection limit <br /> (a) = Surrogate recoveries were outside QC Limits to due matrix effects. <br /> {b) = Surrogate recoveries were not calculated due to dilution of the sample below the detectable range for the surrogate. <br /> (c) = Matrix spike recoveries were outside QC Limits due to matrix effects <br /> (d) = Relative Percent Difference (RPD) for duplicate analysis outside OC limits due to actuat differences in <br /> the sampte matrix. <br /> (e) = The limit Listed for flammability indicates the upper limit for the test SampLes are not tested at temperatures <br /> above 140 Fahrenheit since only saaples which will sustain ignition at temperatures below 140 are considered <br /> f laffeabte. <br /> (f) = Results for this hydrocarbon range did not match a typical hydrocarbon pattern. Results were quantified using a <br /> diesel standard, however, the hydrocarbon pattern did not match a diesel pattern <br /> (g) = ResuLts for this hydrocarbon range did not match a typical hydrocarbon pattern. Results were quantified using a <br /> gasoline standard, however, the hydrocarbon pattern did not match a gasoline pattern <br /> (h) = High dilution due to matrix effects <br /> QC SAMPLE IDEYTIcICATIONS SUBCONTRACTED LABORATORY LOCATIONS <br /> me = Method Stank SB = Storage Blank Core Laboratories Aurora, Colorado *AU <br /> RS = Reagent Stank MS = Matrix Spike Casper, Wyoming *CA <br /> ICS s Initigl Catibration Blank MSD = Matrix Spike Duplicate Carson, California *CP <br /> CCB = Continuing Calibration Blank MD = Matrix Duplicate Corpus Christi, Texas *CC <br /> CS = Calibration Standard SS = Blank Spike Edison, New Jersey *ED <br /> ICY = :nitiat Calibration SS = Surrogate Spike Houston, Texas (Env) *HE <br /> Verification LCS = Laboratory Control Houston, Texas (Pet) *HP <br /> CCY = Continuing Calibration Standard Indianapolis, Indiana *IN <br /> Verification RS = Reference Standard Lake Charles, Louisiana *LC <br /> Valparaiso, Indiana *VP <br /> Bakersfield, California *BK <br /> N1250 Gene Autry Way Autry Way <br /> ' Anaheim, CA 92W5 <br /> (714) 937-1094 /u/matt/togs_n_for=/footer.form <br /> ehn analYhcal esurcs.--.ar t.0.tahwts confalnad w�si ec pat a e bases—na}Orma and mala almpphad by the N"I for wlpae eecWs a xl wnrbant atss� ns r 1 has boon made Tho.maIy,[af to J1.ognlO dr nl0rp ata t o s <br /> ssea apl0sei l the bast ludo mei I of Caa Latwra[ s CMe Lado Id-holve makes r wa anty or apesuntaho Sep ess a SIM ed of any tri a and e o ry d5 ll h e se me.ss to the prd Wfilty Mope opalelw b,p ChMblenass al <br /> any M Q..coil o o al n party—11 0 I-n .1R wf ch sooh repo t s wed or W Id u n lot ary—so +Aietsoa w Tlns repo f sh ill not ba a �C ..I.o oa I wphoul lira w am eW wet of Cas LabMa10 es <br />