My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ARMY
>
1624
>
2300 - Underground Storage Tank Program
>
PR0231014
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/26/2021 8:56:03 AM
Creation date
7/27/2020 2:27:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231014
PE
2361
FACILITY_ID
FA0003777
FACILITY_NAME
ARMY COURT
STREET_NUMBER
1624
STREET_NAME
ARMY
STREET_TYPE
CT
City
STOCKTON
Zip
95206
APN
16334002
CURRENT_STATUS
02
SITE_LOCATION
1624 ARMY CT
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
114
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ 0 A U I N Environmental Health Department <br /> COUNTY— <br /> underground <br /> OU 1TYUnderground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TOYS R US 1 1624 ARMY CT, STOCKTON June 10, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 101 HSC 25284 Failed to obtain a permit to operate from the EHD including but not limited to unpaid permit fees. <br /> A permit to operate the UST system has not been issued. No person may own or operate an UST unless a permit <br /> for its operation has been issued by the local agency to the owner or operator of the UST system. Immediately <br /> obtain a permit to operate a UST system from the EHD. An"Operating without a Permit' penalty may apply. <br /> This is a Class I violation. <br /> 102 HSC 25284(a)(3)(A)/(B) No written agreement between tank owner and tank operator to monitor the tank system. <br /> The annual operating permit is not issued to the current operator and there is no written agreement between the <br /> person who was issued the permit and the operator to monitor the UST system. If a permit is issued to a person <br /> other than the operator of the tank, that person shall enter into a written agreement with the operator of the tank to <br /> monitor the UST system. Immediately submit a copy of this written agreement to the EHD. Alternatively, log into <br /> CERS, upload the written agreement, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 103 HSC 25292.2, 25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> Current financial responsibility documents have not been submitted to the EHD. The Certification of Financial <br /> Responsibility document on CERS is dated 7-5-17. The insurance documents are dated through 7-1-18. Current <br /> financial responsibility documents are required to be submitted annually. Immediately log into the California <br /> Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/, and upload the required documents. <br /> This is a Class II violation. <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Facility Operating Permit is not current in CERS. <br /> -The California Department of Tax and Fee Administration (CDTFA, previously BOE) number listed on CERS is not <br /> associated with the new owner. <br /> Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br /> update the required information, and submit for review by the EHD. <br /> The UST Tank Information form for the diesel tank is not current in CERS. <br /> -No tank manufacturer is listed. <br /> -The installation date is incorrect. <br /> -The tank form states that no striker plates are installed. According to 23 CCR 2631(c), all primary containment shall <br /> have wear plates installed below all accessible openings. Verify that the correct information is submitted and update <br /> the forms or tanks as required. <br /> Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br /> update the <br /> required information, and submit for review by the EHD. <br /> This is a Class II violation. <br /> FA0003777 PR0231014 SCO01 06/10/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.