COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
3212
>
2300 - Underground Storage Tank Program
>
PR0231035
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/21/2021 1:58:58 PM
Creation date
7/27/2020 2:45:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231035
PE
2361
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
01
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM ( page 1 of 1 ) <br /> Type of Action ❑ Installation Inspection ❑ Repair inspection R 36 Month Inspection <br /> 1 . FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 113/2019 <br /> Business Name (Same as Facility Name orDBA•Doing Business As) <br /> Arco 2186 <br /> Business Site Address City ZIP Code <br /> 3212 N California Stockton 195204 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification ) Phone # <br /> David Rouse 1 (925) 551 -4777 <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 220793 8292530 6!28/2026 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications ) V V� f <br /> III . OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑ Manufacturer Guidelines (Specify) : <br /> Used. <br /> Qx Industry Code or Engineering Standard (Specify) Tank charts , OPW Manual , Tape measure <br /> El Engineered Method (Specify) : <br /> Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages <br /> pq <br /> TANK IDs (By tank number, storedproduct, etc.) T1 - Unleaded T1 - Unleaded TMnleaded T3-Premium <br /> What Is the tank Inside diameter? (inches) 120 120 120 120 <br /> Is the fill piping secondarily contained? Q Yes [:1 No EQ Yes [] No (x) Yes O No (] Yes C] No <br /> Is the vent piping secondarily contained? ❑ Yes 0 No 0 Yes [E No 0 Yes I] No 0 Yes [] No <br /> Overfill Prevention Equipment Manufacturer(s) OPW 7150 OPW 7150 OPW 7150 OPW 7150 <br /> i <br /> What is the overfill prevention equipment response ❑ Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow <br /> when activated ? [] Restricts Flow Q Restricts Flow [] Restricts Flow [] Restricts Flow <br /> (Check all that apply. ) <br /> ❑ AN Alarm 0 A/V Alarm ❑ AN Alarm [I AN Alarm <br /> Are flow restrictors installed on vent piping? 0 Yes F!] No 0 Yes [] No ❑ Yes I] No 0 Yes (] No <br /> At what level in the tank is the overfill prevention set 107 107 1063 /8 1061 /2 <br /> to activate? (inches from bottom of tank ) <br /> What is the percent capacity of the lank at which the <br /> overfill prevention equipment activates? 95 95 95 95 <br /> Is the overfill prevention in proper operating condition Yes Q Yes 21 Yes 9 Yes <br /> to respond when the substance reaches the <br /> appropriate level? D No (Specify in V) 0 No (Specify in V ) ❑ No (Specify In V ) [3No (Specify in V) <br /> IV, SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results 0 Pass © Fail Q Pass ❑ Fail El Pass ❑ Fail E] Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked "Fait" must be explained in this section . Any additional comments may also be provided here <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was Inspected in accordance with California Code of Regulations , Title 23, <br /> Division 3 , Chapter 16, Section 2637. 2 and all the Vforni contained herein Is accurate . <br /> UST Service Technician Signature <br /> I f the facility has more components W this form accommodates, additional copies of this page may be attached. <br /> CERS = California Ernirorvnental Reporting System. 113 = Identification. UST = Underground Storage Tank, ICC = International Code Council. AN = Audible and Visual <br />