My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
440
>
2300 - Underground Storage Tank Program
>
PR0231055
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2023 3:10:24 PM
Creation date
7/27/2020 2:53:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231055
PE
2361
FACILITY_ID
FA0002321
FACILITY_NAME
Delta arco
STREET_NUMBER
440
Direction
W
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
16503003
CURRENT_STATUS
01
SITE_LOCATION
440 W DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br />OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page t of 1) <br />Type of Action ❑ Installation Inspection ❑ Repair Inspection i] 36 Month Inspection <br />I. FACILITY INFORMATION <br />CERS ID Date of Overfill Prevention Equipment Inspection <br />10180903 4/4/2019 <br />Business Name (Same as Facility Name or DBA-Doing Business As) <br />DELTA ARCO <br />Business Site Address City ZIP Code <br />440 WEST CHARTER WAY STOCKTON 95206 <br />II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br />Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone # <br />David Winkler 1 (209) 744-0112 <br />Contractor I Tank Tester License # ICC Certification # ICC Certification Expiration Date <br />08-1739 Ex.3/31/2020 8883059-UT 1/29/2020 <br />Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br />F- EBW , PhikTite & EVR Phase 1 1009853708 Ex 11A6-20 OPW 104-633 Ex 3-14-2020 <br />Emco #3207 Ex. 09-21-2020 VR: B34975 ATG: 2/8/20 <br />III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br />Inspection Method N Manufacturer Guidelines (Specify): <br />Used: REMOVED OPW DROP TUBES <br />❑ Industry Code or Engineering Standard (Specify): <br />❑ Engineered Method (Specify): <br /># of Attached Pages <br />Attach the inspection procedures and all documentation required to determine the results. 4 <br />TANK ID: (By tank number, stored product, etc.) 87 91 <br />What is the tank inside diameter? (Inches) 128 96 <br />Is the fill piping secondarily contained? ❑ Yes ❑x No ❑ Yes ❑x No ❑ Yes ❑ No KShuts <br />❑ No <br />Is the vent piping secondarily contained? ❑ Yes N No ❑ Yes Z No ❑ Yes ❑ No ❑ No <br />Overfill Prevention Equipment Manufacturer(s) oPw OPW <br />61SO 61SO <br />What is the overfill prevention equipment response N Shuts Off Flow N Shuts Off Flow ❑ Shuts Off Flow Flow <br />when activated? <br />(Check all that apply) El Restricts Flow El Restricts Flow E] Restricts Flow El Restricts Flow <br />❑ AN Alarm ❑ AN Alarm ❑ AN Alarm ❑ AN Alarm <br />Are flow restrictors installed on vent piping? ElYes Z No ElYes No ❑Yes ❑ No El Yes El No <br />At what level in the tank is the overfill prevention set <br />to activate? (Inches from bottom of tank) 113 83 <br />What is the percent capacity of the tank at which the <br />overfill prevention equipment activates? 93 92 <br />Is the overfill prevention in proper operating condition N Yes ❑x Yes ❑ Yes ❑ Yes <br />to respond when the substance reaches the <br />appropriate level? I ❑ No (Specify in V.) ❑ No (Specify in V.) ❑ No (Specify in V) ❑ No (Specify in V.) <br />IV. SUMMARY OF INSPECTION RESULTS <br />Overfill Prevention Inspection Results.]N Pass Fail [EPass ❑Fail ❑Pass ❑Fail Overfill ❑Fail <br />V. COMMENTS <br />Any items marked "Fail' must be explained in this section. Any additional comments may also be provided here. <br />RECEIVED <br />Hi I etlo i <br />VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br />I hereby certify that the overfill prevention equipment was inspected in accordance with,C, lif'pp,rn�}'� �jRp�d ppf R ggul��tt res, le 23, <br />Division 3, Chapter 16, Section 2637.2 and all the information contained herein is accrirj <br />pp <br />{111�Kilt? I L H�HL• <br />IH <br />UST Service Technician Signature ^ j <br />If the facility has more components than this form accommodates, additional copies of this page maybe attached. <br />CERS = Cal'rfomia Environmental Reporting System, ID = Identification, UST =Underground Storage Tank, ICC = International Code Council, AA/ =Audible and Vi <br />sual <br />
The URL can be used to link to this page
Your browser does not support the video tag.