Laserfiche WebLink
i <br />� i15 May 2001 <br /> AGE-NC Project No 97-0333 <br /> ' Page 6 of 7 <br /> D, E and F) <br /> • Utilizing a semi-loganthmic plot of ground water draw- <br /> down vs observation well distance <br /> to pumping well(Jacob straight-line method),a best-fit line can be utilized to project a radius <br /> of influence of approximately 140 feet at 6 GPM (Appendix H) <br /> • Utilizing the Distance-Drawdown Method (Jacob straight-line method), a transmissivity was <br /> ' calculated at 955 ft'/day (equivalent to 7,127 gallons per day/ft) and a storativity value <br /> calculated at 0 032 (Appendix I) <br /> • Based on a transmissivity value of 955 ft'/day and the First Water Zone aquifer thickness <br /> ' equaI to 25 ft(screen interval at EW-1),a hydraulic conductivity value was calculated at 38 2 <br /> ft/day, or 0 0135 cm/s (Appendix 1), a hydraulic conductivity of 0 0135 cm/s is consistent <br /> with a screened interval located within a well sorted sand to clean sand (Appendix L) <br /> • Laboratory analysis of extracted water during the pumping test detected elevated <br /> concentrations of TPH-g, BTEX, MTBE and TAME, TPH-d was detected, however, the <br /> laboratory reported the sample chromatogram as a non-diesel pattern and significant lighter <br /> range gasoline compounds (Appendix J) <br /> 5.0 RECOMMENDATIONS <br /> By letter dated 02 March 2001, the RWQCB directed the Rainwater Car Wash to install and <br /> continuously operate an interim pump and treat system in the area of the most-intense on-site ground <br /> water contamination <br /> Based on the 05 April 2001 ground water aquifer pumping test results, AGE recommends interim <br /> remediation by extracting petroleum-impacted ground water from EW-1 at approximately 6 GPM, <br /> based on the site's estimated radius of influence of at least 140 feet and site specific aquifer <br /> ' characteristics inferred from the pumping test, AGE believes that ground water extraction from well <br /> EW-1 at 6 GPM will effectively stabilize the groundwater plume and inhibit further migration of <br /> petroleum-impacted ground water off-site until a full-scale ground water remediation system can be <br /> ' implemented <br /> Extracted ground water from EW-1 could be treated through an on-site two-stage ground water <br /> pump-and-treat system The first stage of the ground water pump and treat system would utilize <br /> granular activated carbon (GAC) to address TPH-g, TPH-d and BTEX in extracted ground water, <br /> the second stage of treatment would address MTBE utilizing SunSolve, a patented material that has <br /> ' an affinity to absorb MTBE Following treatment, water could then be discharged into the City of <br /> Manteca sewer system under a City of Manteca Public Works permit <br /> ' 4dvaiared C,coEntiironmLotjl Inc <br />