Laserfiche WebLink
nU1� SAN J OAQ U I N Environmental Health Department <br /> a z Linda Turkatte, REHS, Director <br /> COUNTY <br /> � P Kasey Foley, REHS,Assistant Director <br /> Greatness grows here. <br /> PROGRAM COORDINATORS <br /> Robert McClellon, REHS <br /> Jeff Carruesco, REHS, RDI <br /> Rodney Estrada, REHS <br /> Willy Ng, REHS <br /> Muniappa Naidu, REHS <br /> August 15, 2018 <br /> MEGAN MITCHELL n <br /> ELITE IV CONTRACTORS � FRE caps <br /> 2535 WIGWAM DR <br /> STOCKTON, CA 95205 <br /> Re: EMILS LIQUOR & SPORTS SHOP` SR0079474 <br /> 1405 CALIFORNIA ST <br /> ESCALON, CA 95320 <br /> The San Joaquin County Environmental Health Department(EHD) has completed the review of the <br /> application for a permit to Install Bravo deflector plates on all dispensers and replace directly buried <br /> diesel-product spill container with OPW(OPW 1 C-2100-DEVR) 5 gallon spill container on the <br /> underground storage tank (UST) system at the above noted address. The permit has been approved with <br /> the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control District for any <br /> applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Zuna Barker at(209) 953-7311 to arrange the following appointments (a 48-hour notice is <br /> required for inspection appointments). <br /> • Spill bucket test: Verify minimum 5-gallon capacity and pass a one hour hydrostatic test(or <br /> equivalent). Proper drainage must also be verified. <br /> • Corrosion protection: Verify corrosion protection for direct bury spill bucket prior to backfilling. <br /> • Verification of the dispenser footprints contained by the under dispenser containment sumps <br /> (U DCs) <br /> • Visual inspection of the piping within the dispensers <br /> Please be aware that the facility cannot operate the UST system prior to the EHD inspection <br /> and approval. <br /> Please be aware that the facility cannot receive fuel in the tank prior to the EHD inspection <br /> and approval. <br /> 4. Since concrete will be broken near the tank, a secondary containment test must be performed on the <br /> tank once concrete is poured in accordance with the manufacturer's guidelines. <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />