COMPLIANCE INFO_2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
1405
>
2300 - Underground Storage Tank Program
>
PR0231485
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2020 12:28:54 PM
Creation date
7/28/2020 10:20:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231485
PE
2361
FACILITY_ID
FA0000306
FACILITY_NAME
EMILS LIQUOR & SPORTS SHOP*
STREET_NUMBER
1405
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
ESCALON
Zip
95320
APN
22707031
CURRENT_STATUS
01
SITE_LOCATION
1405 CALIFORNIA ST
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI , <br /> MONITORING SYSTEM CERTIFICATION ` <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code; Chapter 16,Division 3,Title 23,California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for ENVIRONMENTAL <br /> DEPARTMENTeach monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system IEALTH L <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test dat . <br /> A. General Information <br /> Facility LIQUOR& SPORTS SHOP Bldg.No.: <br /> Site <br /> Address- 1405 CALIFORNIA ST. city: ESCALON Z;P: 95320 <br /> Facility Contact CHACKO <br /> Person Contact Phone No.: (209)838-7674 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 6/27/2018 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the aggro, riate boxes to indicatespecific equipment inspected/serviced: <br /> Tank ID: 87 Tank Size: Tank ID: 91 Tank Size: <br /> ® In-Tank Gauging Probe. Model: MAG-2 ® In-Tank Gauging Probe. Model: MAG-2 <br /> ® Annular Space or Vault Sensor. Model: 420 ® Annular Space or Vault Sensor. Model: 420 <br /> ® Piping Sump/Trench Sensor(s). Model: 208 ® Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ® Mechanical Line Leak Detector. Model: LD 2000 ® Mechanical Line Leak Detector. Model: FXIV <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: DIE Tank Size: Tank ID: Tank Size: <br /> ® In-Tank Gauging Probe. Model: MAG-2 ❑ In-Tank Gauging Probe. Model: <br /> ® Annular Space or Vault Sensor. Model: 420 ❑ Annular Space or Vault Sensor. Model: <br /> ® Piping Sump/Trench Sensor(s). Model: 208 ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ® Mechanical Line Leak Detector. Model: FXIV ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 DispenserlD: 3-4 <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ® Dispenser Containment Float(s)and Chain(s). ® Dispenser Containment Float(s)and Chain(s). <br /> Dispenser lD: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ® Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment <br /> ❑ Dispenser Containment Sensor(s). Model: Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> "If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): ®System set-up ®Alarm history report <br /> Technician Name(print): ED STEARNS Signature: fid _� - <br /> Certification No.: A31048 License No: <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 <br /> Testing Company Address: 416 2nd STREET GALT,CA 95632 Date of Testing/Servicing: 6/27/18 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br />