My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0082330 SSNL
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MARIPOSA
>
1754
>
2600 - Land Use Program
>
SR0082330 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/1/2020 4:22:12 PM
Creation date
7/29/2020 2:38:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0082330
PE
2602
FACILITY_NAME
MURRAY TRAILERS
STREET_NUMBER
1754
Direction
E
STREET_NAME
MARIPOSA
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
17304004
ENTERED_DATE
7/15/2020 12:00:00 AM
SITE_LOCATION
1754 E MARIPOSA RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
feet. When necessary after measuring the water level, the hole was refilled with water <br /> to a level of approximately six inches above the bottom of the hole. <br /> Percolation Test Results <br /> The completed percolation test form is included in Appendix 3 of this report. The form <br /> was signed by Ms. Kaur and indicates a percolation rate for the hole based on the least <br /> water drop observed. <br /> Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is greater than or equal to 1 minute per inch (min/in) but less than <br /> or equal to 60 min/in drop. For the Site to utilize a standard septic system, one <br /> percolation test must demonstrate a satisfactory percolation rate within the proposed <br /> septic system disposal field. <br /> Details and results of the percolation test are summarized in the following table. <br /> Table 2. Percolation Test Summary <br /> Test No., Percolation Test Percolation Rate Test Duration Comments <br /> Date Tested Depth (ft.) (minutes/inch) (see notes) <br /> P1, <br /> 6/23/2020 3.50 3.8 1 hr. Satisfactory perc. <br /> Shallow Test rate <br /> Note: A satisfactory percolation rate for a "shallow" test is greater than 1 but less than or equal to 60 minutes per <br /> inch. <br /> 1 Per San Joaquin County Environmental Health Department, a rate between 1.0 and 5.0 min/in requires a <br /> 20-foot separation between the bottom of dispersal system and ground water, or mitigation by system <br /> design or enhancement. <br /> Discussion of Percolation Test Results <br /> The soils within the proposed sewage disposal area of the Site have demonstrated a <br /> satisfactory percolation rate for the use of a standard septic system in accordance with <br /> the requirements of the San Joaquin County Environmental Health Department. This <br /> percolation test is considered representative of soils within a 100-foot radius of the test <br /> location. <br /> Because of the percolation rate between 1.0 and 5.0 min/in encountered in the test <br /> hole, the San Joaquin County Environmental Health Department will require a 20-foot <br /> separation from the bottom of the dispersal system to ground water. Ground water is <br /> anticipated to be encountered approximately 55 to 61 feet below ground surface at the <br /> Site; consequently, no modifications to standard septic systems should be required. <br /> LOGE 20-24 Page 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.