Laserfiche WebLink
Nitrate Loading Calculations: <br /> Variable Value Units Description <br /> Q 285 gallons per day Effluent flow rate from report <br /> Nw 85 mg/L-N Effluent stream concentration from report <br /> A 13.74 acres Site area from report <br /> Nb 0.30 mg/L-N Concentration of rain water from report <br /> d 0.35 constant Denitrification factor from report <br /> R 4.04 inches per year Recharge rate of rainfall from report <br /> W 0.3 inches per year Uniform waste water loading for site calculation result <br /> Nc 3.8 mg/L-N RESULT. Long-term average concentration of percolating effluent <br /> Find Variable W <br /> (VV) in = (Q) gal x 1 W x 365 da x 1 acre x 12 in x 1 site <br /> yr day 7.48 gal 1 year 43,560 ft2 1 ft (A)acre(s) <br /> 0.28 in/yr(site)=285 gal/day x(1 cu-ft/7.48 gals)x(365 days/1 year)x(1 acre/43,560 sq-ft)x(12 in/1 ft)x(1 site/13.74 acres) <br /> Hantzsche-Fennemore Equation(Nc): <br /> N�= WN-O-d)+RN. <br /> W+R <br /> 3.85 mg/L-N=((0.28 in/yr x 85 mg/L-N x(1-0.35))+(4.04 in/yr x 0.3mg4.-N))/(0.28 in/yr+4.04 in/yr) <br /> Assumptions: <br /> 1. Total nitrogen concentration of influent waste stream is 85 mg/L-N. If different influent concentrations exist,use weighted average <br /> 2. Fraction of nitrate-N loss due to denitrification in the soil is 35%. <br /> 3. Estimated deep percolation of rainfall is 4.04 in/yr. <br /> 4. Background nitrate-N concentration of rainfall is 0.3 mg/L-N. <br /> Plate No.: 16 <br /> Nitrate Loading Calculation <br /> _AMJWb,r <br /> ` Project No: 20-24 <br /> __ Murray Trailers <br /> LIVE OAK 1754 S.Mariposa Rd. Date: July 8,2020 <br /> GEO ENVIRONMENTAL INC. Stockton,CA <br />