Laserfiche WebLink
FGL <br /> ENVIRONMENTAL AGRICULTURAL <br /> Analytical(Iienlists <br /> June 23,2020 Lab ID : STK2038323 <br /> Live Oak Geo Environmental Customer : 3-16608 <br /> Quality Control - Organic <br /> Constituent Method Date/ID Type Units Conc. QC Data DQO Note <br /> Organic <br /> 1,2-Dibromoethane(EDB) 50.1 06/16/20:206729MCA QMDL ug/L 0.01898 102% 60-140 <br /> Blank ug/L ND <0.02 <br /> LCS ug/L 0.2413 95.0% 70-130 <br /> LES ug/L 0.2411 96.9% 70-130 <br /> MS ug/L 0.2457 91.9% 70-130 <br /> (STK2038153-001) MSD ug/L 0.2427 93.2% 70-130 <br /> MSRPD u /L 0.5695 03% <30 <br /> 1,3-Dibromopropane 504 06/16/20:206729MCA QMDL ug/L 0.5609 91.5% 70-130 <br /> Blank ug/L 0.5728 79.6% 70-130 <br /> LCS ug/L 0.5663 96.9% 70-130 <br /> LCS ug/L 0.5658 102% 70-130 <br /> MS ug/L 0.5766 90.9% 70-130 <br /> (STK2038153-001) MSD ug/L 0.5695 96.4% 70-130 <br /> MSRPD I u /L 0.5695 4.7% 1 <30 <br /> DB('P 504 06/16/20:206729MCA QMDL ug/L 0.01898 873% 60-140 <br /> Blank ug/L ND <0.01 <br /> LCS ug/L 0.2413 86.7% 70-130 <br /> LCS ug/L 0.2411 89.1% 70-130 <br /> MS ug/L 0.2457 793% 70-130 <br /> (STK2038153-001) MSD ug/L 0.2427 82.9% 70-130 <br /> MSRPD I u /L 0.5695 1 3.0% S30 <br /> 131)BP 504.1 06/18/20:209466MCA CCV ug/L 9.975 95.7% 70-130 <br /> CCV u /L 7.481 100% 70-130 <br /> DBCP 504.1 06/18/20:209466MCA CCV ug/L 5.000 84.2% 70-130 <br /> CCV u /L 2.000 92.5% 70-130 <br /> EDB 504.1 06/18/20:209466MCA CCV ug/L 5.000 92.2% 70-130 <br /> CCV u /L 2.000 92.5% 701130 <br /> Definition <br /> CCV :Continuing Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> Blank :Method Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> LCS :Laboratory Control Standard/Sample-Prepared to verify that the preparation process is not affecting analyte recovery. <br /> MS :Matrix Spikes-A random sample is spiked with a known amount of analyte.The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD :Matrix Spike Duplicate of MS/MSD pair-A random sample duplicate is spiked with a known amount of analyte.The recoveries <br /> are an indication of how that sample matrix affects analyte recovery. <br /> MSRPD :MS/MSD Relative Percent Difference(RPD)-The MS relative percent difference is an indication of precision for the preparation <br /> and analysis. <br /> ND :Non-detect-Result was below the DQO listed for the analyte. <br /> O :Data Quality Objective-This is the criteria against which the quality control data is compared. <br /> Page 6 of 7 <br /> Corporate Offices&Laboratory Office&Laboratory Office&Laboratory Office&Laboratory Office&Laboratory <br /> 853 Corporation Street 2500 Stagecoach Road 563 E.Undo Avenue 3442 Empresa Drive,Suite D 9415 W Goshen Avenue <br /> Santa Paula,CA 93060 Stockton,CA 95215 Chico,CA 95926 San Luis Obispo,CA 93401 Visalia,CA 93291 <br /> TEL:(805)392-2000 TEL:(209)942-0182 TEL:(530)343-5818 TEL:(806)783-2940 TEL:(559)734-9473 <br /> Env FAX:(805)525-4172/Ag FAX:(805)392-2063 FAX:(209)942-0423 FAX:(530)343-3807 FAX:(805)783-2912 FAX:(559)734-8435 <br /> CA ELAP Certification No.1573 'CA ELAP Certification No.1563 CA ELAP Certification No.2670 CA ELAP Certification No.2775 CA ELAP Certification No.2810 <br />