Laserfiche WebLink
SAN" J D�l+ �� I 11411" Environmental Health Department <br /> COUNTY— <br /> Underground <br /> �l O U N T Y— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FOOD MART GASOLINE* 2185 E FREMONT ST STOCKTON Se tember 24 2019 <br /> Single-Walled Non-Pressurized Piping <br /> 402 CCR 2643(d) Failure to conduct monitoring/maintain records for single-walled conventional suction(pre-1984) ❑V ❑R ❑COS <br /> 403 CCR 2643(d),2661(f) Failure to conduct 0.1 gph test for single-walled conventional suction systems(pre-Jan 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e),2661(f) 0.1-gph line test for single-walled gravity piping not performed biennialy or post repair(pre-1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 319 CCR 2635, 2637.1,2665, 2712 No spill bucket,failed to contain 5 gallons, no means to keep it empty, or failed to be <br /> tested. <br /> The 87 and diesel product spill containers failed to have a minimum capacity of five gallons. All spill containers shall <br /> have a minimum capacity of five gallons. Immediately contact a properly licensed,trained, and certified contractor to <br /> repair or replace the spill container under permit and inspection of the EHD. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator at the time of inspection. The EHD will generate and <br /> provide a complete report to the facility operator. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receiving the complete inspection report. <br /> Documents provided: <br /> -EHD class schedule <br /> -Gasoline Advertising Signs <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br /> FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: September 24, 2019 Inspector: Inspector Phone: <br /> _ �� Pte— Printed Name and Title: SHEWIT WOLDEAREGAY, EH Specialist (209)468-0216 <br /> Ashish Boveja, Operator <br /> FA0003284 PR0231118 SCO01 09/24/2019 <br /> EHD 23-01 Rev.08/27/2019 Page 4 of 4 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />