Laserfiche WebLink
z SAN JOAQUIN p <br /> °mac° Environmental Health Department <br /> 1 <br /> COUNTY Linda Turkatte , REHS , Director <br /> (I Greatness grows here . <br /> Kasey Foley , REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS, RDI <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> Michael Kith , REHS <br /> December 13 , 2019 <br /> Megan Mitchell <br /> Elite IV Contractors <br /> 2535 Wigwam Dr . <br /> Stockton , CA 95205 <br /> Re : Food Mart Gasoline SR0081376 <br /> 2185 E . Fremont St . , Stockton , CA 95205 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a 1 hour plan check service request to replace the 87 and diesel spill containers ( in fill <br /> sumps ) on the underground storage tank ( UST) system at the above noted address . The plan check <br /> service request has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ustCc sigov . org for the following repairs and testing ( a 48 - hour <br /> notice is required ) . Please be aware that inspections for emergency work must be scheduled <br /> within five days of plan check service request approval . <br /> a . Spill bucket test : Verify minimum 5 -gallon capacity and pass a one hour hydrostatic test ( or <br /> equivalent) . Proper drainage must also be verified . <br /> 4 . If concrete will be broken near the sumps or piping , a secondary containment test must be <br /> performed on the affected components once concrete is poured in accordance with the <br /> manufacturer' s guidelines , and test results submitted to the EHD within 30 days of testing . <br /> 5 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be issued <br /> to the installation company) , or a Tank Tester' s license issued to the individual by the State <br /> Water Board , and <br /> b . Possess or work under the direct and personal supervision of an individual physically <br /> present at the work site who possesses a valid , current California UST Service Technician <br /> certificate issued by the International Code Council ( ICC ) , and <br /> c . Possesses a valid , current certificate of training from the manufacturer(s ) of the <br /> component ( s) being tested , repaired , or serviced . <br /> 6 . Individuals installing underground storage tank system components must possess or work <br /> under the direct and personal supervision of an individual physically present at the work site <br /> who possesses all of the following : <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468 -3420 F 209 464-0138 1 www . sjcehd . com <br />